2006Journal of Refractive SurgeryRequires access

A Correction Formula for the Real Intraocular Pressure After LASIK for the Correction of Myopic Astigmatism

Markus Kohlhaas, Eberhard Spoerl, Andreas Boehm, Katharina Pollack

Open publisher page 69 citations

Abstract

PURPOSE: To create a correction formula to determine the real intraocular pressure (IOP) after LASIK considering the altered corneal thickness, corneal curvature, and corneal stability. METHODS: This prospective clinical trial comprised 101 eyes of 59 patients (34 women and 25 men) that underwent LASIK with a mean preoperative spherical equivalent refraction of -6.3 +/- 2.17 diopters (D) (-3.0 to -11.5 D). Mean patient age was 32 +/- 9 years. Preoperatively and 6 months postoperatively, IOP (by Goldmann applanation tonometry), keratometry (by topography), and central corneal thickness (CCT) (by ultrasound pachymetry) were evaluated. These parameters were measured in all patients between 8 and 11 o'clock in the morning. RESULTS: Due to the LASIK procedure, IOP was reduced from 16.5 +/- 2.1 mmHg (range: 12 to 22 mmHg) to 12.9 +/- 1.9 mmHg (range: 8 to 16 mmHg). Multiple linear regression analysis of the IOP values before and after LASIK showed a significant correlation between the measured IOP and CCT and keratometry values (R2=0.631; P<.001). After LASIK, the biomechanical bending strength of the cornea is reduced by the cut so that the measured IOP must be additionally corrected by 0.75 mmHg. An equation containing all three changes is given: IOP (real) = IOP (measured) + (540-CCT)/71 + (43-K-value)/2.7 + 0.75 mmHg. CONCLUSIONS: Intraocular pressure measurements after LASIK for the correction of myopia are inaccurate as a consequence of changes in CCT, corneal curvature, and corneal flap stability. After LASIK, the measured IOP should be corrected to avoid false low IOP applanation readings.

About this research paper

What this paper is about

PURPOSE: To create a correction formula to determine the real intraocular pressure (IOP) after LASIK considering the altered corneal thickness, corneal curvature, and corneal stability. METHODS: This prospective clinical trial comprised 101 eyes of 59 patients (34 women and 25 men) that underwent LASIK with a mean preoperative spherical equivalent refraction of -6.3 +/- 2.17 diopters (D) (-3.0 to -11.5 D). Mean patient age was 32 +/- 9 years. Preoperatively and 6 months postoperatively, IOP (by Goldmann applanation tonometry), keratometry (by topography), and central corneal thickness (CCT) (by ultrasound pachymetry) were evaluated. These parameters were measured in all patients between 8 and 11 o'clock in the morning. RESULTS: Due to the LASIK procedure, IOP was reduced from 16.5 +/- 2.1 mmHg (range: 12 to 22 mmHg) to 12.9 +/- 1.9 mmHg (range: 8 to 16 mmHg). Multiple linear regression analysis of the IOP values before and after LASIK showed a significant correlation between the measured IOP and CCT and keratometry values (R2=0.631; P<.001). After LASIK, the biomechanical bending strength of the cornea is reduced by the cut so that the measured IOP must be additionally corrected by 0.75 mmHg. An equation containing all three changes is given: IOP (real) = IOP (measured) + (540-CCT)/71 + (43-K-value)/2.7 + 0.75 mmHg. CONCLUSIONS: Intraocular pressure measurements after LASIK for the correction of myopia are inaccurate as a consequence of changes in CCT, corneal curvature, and corneal flap stability. After LASIK, the measured IOP should be corrected to avoid false low IOP applanation readings.

Why it matters

OpenAlex reports 69 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To create a correction formula to determine the real intraocular pressure (IOP) after LASIK considering the altered corneal thickness, corneal curvature, and corneal stability. METHODS: This prospective clinical trial comprised 101 eyes of 59 patients (34 women and 25 men) that underwent LASIK with a mean preoperative spherical equivalent refraction of -6.3 +/- 2.17 diopters (D) (-3.0 to -11.5 D). Mean patient age was 32 +/- 9 years. Preoperatively and 6 months postoperatively, IOP (by Goldmann applanation tonometry), keratometry (by topography), and central corneal thickness (CCT) (by ultrasound pachymetry) were evaluated. These parameters were measured in all patients between 8 and 11 o'clock in the morning. RESULTS: Due to the LASIK procedure, IOP was reduced from 16.5 +/- 2.1 mmHg (range: 12 to 22 mmHg) to 12.9 +/- 1.9 mmHg (range: 8 to 16 mmHg). Multiple linear regression analysis of the IOP values before and after LASIK showed a significant correlation between the measured IOP and CCT and keratometry values (R2=0.631; P<.001). After LASIK, the biomechanical bending strength of the cornea is reduced by the cut so that the measured IOP must be additionally corrected by 0.75 mmHg. An equation containing all three changes is given: IOP (real) = IOP (measured) + (540-CCT)/71 + (43-K-value)/2.7 + 0.75 mmHg. CONCLUSIONS: Intraocular pressure measurements after LASIK for the correction of myopia are inaccurate as a consequence of changes in CCT, corneal curvature, and corneal flap stability. After LASIK, the measured IOP should be corrected to avoid false low IOP applanation readings.

Key concepts: LASIK, Keratometer, Dioptre, Intraocular pressure, Ophthalmology, Medicine, Corneal topography, Cornea

Related papers

Back to paper searchBrowse research topicsOriginal source
A Correction Formula for the Real Intraocular Pressure After LASIK for the Correction of Myopic Astigmatism — Research Paper | ScholarLens