2000PubMedRequires access

[Summary of the guideline 'Sentinel node biopsy in breast cancer.' Dutch Work Group 'Sentinel Node Biopsy for Breast Cancer'].

Roumen Rm, Pijpers Hj, Erik Thunnissen, Ruers Tj

Open publisher page 23 citations

Abstract

The team Sentinel Node Biopsy Breast Cancer issued guidelines for the performance of the sentinel node procedure. The team took into account the problems resulting from the introduction of the technique. The eligible group consists mainly of women with demonstrated breast cancer with a diameter of < or = 2 cm without palpable axillary nodes. Contraindications include presence of more than one tumour, pathological nodes in the ipsilateral axilla and previous treatment of breast or axilla. After injection of a radioactive substance, the sentinel node is detected during the operation using a gamma probe. The tracer is injected 2 to 24 hours before the operation in or near the tumour. Shortly before the incision, patent blue is injected as well, improving the detectability of the sentinel node. One or several sentinel nodes are examined histologically. The pathology report meets minimal requirements. In the planning and introduction of the technique in a hospital a locally responsible radiation expert should be involved. The procedure should be performed a number of times and evaluated with reference to a histopathological result before it is decided to draw clinical conclusions from the procedure. For the necessary evaluations of the procedure central registration is an absolute condition.

About this research paper

What this paper is about

The team Sentinel Node Biopsy Breast Cancer issued guidelines for the performance of the sentinel node procedure. The team took into account the problems resulting from the introduction of the technique. The eligible group consists mainly of women with demonstrated breast cancer with a diameter of < or = 2 cm without palpable axillary nodes. Contraindications include presence of more than one tumour, pathological nodes in the ipsilateral axilla and previous treatment of breast or axilla. After injection of a radioactive substance, the sentinel node is detected during the operation using a gamma probe. The tracer is injected 2 to 24 hours before the operation in or near the tumour. Shortly before the incision, patent blue is injected as well, improving the detectability of the sentinel node. One or several sentinel nodes are examined histologically. The pathology report meets minimal requirements. In the planning and introduction of the technique in a hospital a locally responsible radiation expert should be involved. The procedure should be performed a number of times and evaluated with reference to a histopathological result before it is decided to draw clinical conclusions from the procedure. For the necessary evaluations of the procedure central registration is an absolute condition.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The team Sentinel Node Biopsy Breast Cancer issued guidelines for the performance of the sentinel node procedure. The team took into account the problems resulting from the introduction of the technique. The eligible group consists mainly of women with demonstrated breast cancer with a diameter of < or = 2 cm without palpable axillary nodes. Contraindications include presence of more than one tumour, pathological nodes in the ipsilateral axilla and previous treatment of breast or axilla. After injection of a radioactive substance, the sentinel node is detected during the operation using a gamma probe. The tracer is injected 2 to 24 hours before the operation in or near the tumour. Shortly before the incision, patent blue is injected as well, improving the detectability of the sentinel node. One or several sentinel nodes are examined histologically. The pathology report meets minimal requirements. In the planning and introduction of the technique in a hospital a locally responsible radiation expert should be involved. The procedure should be performed a number of times and evaluated with reference to a histopathological result before it is decided to draw clinical conclusions from the procedure. For the necessary evaluations of the procedure central registration is an absolute condition.

Key concepts: Medicine, Sentinel node, Breast cancer, Axilla, Sentinel lymph node, Biopsy, Guideline, Cancer

Related papers

Back to paper searchBrowse research topicsOriginal source
[Summary of the guideline 'Sentinel node biopsy in breast cancer.' Dutch Work Group 'Sentinel Node Biopsy for Breast Cancer']. — Research Paper | ScholarLens