[Perinatal monitoring in intrahepatic cholestasis of pregnancy].
S Liu, Yefeng Cai, M Qie
Abstract
S Liu, Yefeng Cai, M Qie
Abstract
The sensitivity of meconium stain in amniotic fluid for prediction of fetal well-being in intrahepatic cholestasis of pregnancy(ICP) was evaluated. The study consisted of an ICP group(n = 30), and a control group (n = 30) and the umbilical arterial pH value(< 7.2) was used as a standard. The positive and negative predicttive valus of meconium-stained amniotic fluid in ICP group were 80.0%; the positive and negative predictive values in control group were 60.0% and 92.0% respectively. There was no significant difference (P > 0.05) between the two groups in positive and negative predictive values. However, the positive and negative predictive values of the two groups were high, which indicated that meconium-stained amniotic fluid related to fetal hypoxia. Moreover, the incidence of meconium-stained amniotic fluid in ICP was higher than that in control (40.0%: 16.70%, P < 0.05). Therefore, we suggest that the amniotic fluid of patients with ICP should be observed very closely. When meconium-stained amniotic fluid is discovered, delivery by cesarean section is imminent.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The sensitivity of meconium stain in amniotic fluid for prediction of fetal well-being in intrahepatic cholestasis of pregnancy(ICP) was evaluated. The study consisted of an ICP group(n = 30), and a control group (n = 30) and the umbilical arterial pH value(< 7.2) was used as a standard. The positive and negative predicttive valus of meconium-stained amniotic fluid in ICP group were 80.0%; the positive and negative predictive values in control group were 60.0% and 92.0% respectively. There was no significant difference (P > 0.05) between the two groups in positive and negative predictive values. However, the positive and negative predictive values of the two groups were high, which indicated that meconium-stained amniotic fluid related to fetal hypoxia. Moreover, the incidence of meconium-stained amniotic fluid in ICP was higher than that in control (40.0%: 16.70%, P < 0.05). Therefore, we suggest that the amniotic fluid of patients with ICP should be observed very closely. When meconium-stained amniotic fluid is discovered, delivery by cesarean section is imminent.
Key concepts: Amniotic fluid, Meconium, Cholestasis of pregnancy, Medicine, Obstetrics, Fetus, Pregnancy, Meconium aspiration syndrome