1999•PubMedRequires access

[Study on the analytical method of methyl-parathion and phoxim in methyl-parathion, phoxim and cypermethrin mixed formulation].

Y Wang, F Zheng, F Chen

Open publisher page 0 citations

Abstract

This paper describes an HPLC method to simultaneously determine methyl-parathion and phoxim in mixed formulation of methyl-parathion, phoxim and cypermethrin. A C8 column was used. The mobile phase was V(MeOH):V(H2O) = 70:30, Methyl-parathion and phoxim were monitored at 254 nm or 280 nm by UV detector. The average recoveries were 99.8% and 99.9% for methyl-parathion and phoxim respectively. The linearity of detector response vs concentration was calibrated in the concentration ranges from 0.1746 to 1.091 g/L for methyl-parathion and from 0.1927 to 1.205 g/L for phoxim.

About this research paper

What this paper is about

This paper describes an HPLC method to simultaneously determine methyl-parathion and phoxim in mixed formulation of methyl-parathion, phoxim and cypermethrin. A C8 column was used. The mobile phase was V(MeOH):V(H2O) = 70:30, Methyl-parathion and phoxim were monitored at 254 nm or 280 nm by UV detector. The average recoveries were 99.8% and 99.9% for methyl-parathion and phoxim respectively. The linearity of detector response vs concentration was calibrated in the concentration ranges from 0.1746 to 1.091 g/L for methyl-parathion and from 0.1927 to 1.205 g/L for phoxim.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper describes an HPLC method to simultaneously determine methyl-parathion and phoxim in mixed formulation of methyl-parathion, phoxim and cypermethrin. A C8 column was used. The mobile phase was V(MeOH):V(H2O) = 70:30, Methyl-parathion and phoxim were monitored at 254 nm or 280 nm by UV detector. The average recoveries were 99.8% and 99.9% for methyl-parathion and phoxim respectively. The linearity of detector response vs concentration was calibrated in the concentration ranges from 0.1746 to 1.091 g/L for methyl-parathion and from 0.1927 to 1.205 g/L for phoxim.

Key concepts: Phoxim, Parathion methyl, Parathion, Chromatography, Chemistry, Pesticide, Biology, Ecology

Related papers

Back to paper searchBrowse research topicsOriginal source
[Study on the analytical method of methyl-parathion and phoxim in methyl-parathion, phoxim and cypermethrin mixed formulation]. — Research Paper | ScholarLens