1986PubMedRequires access

Effect of Sn(II) ion concentration and heparin on technetium-99m red blood cell labeling.

S A Rao, J Knobel, Collier Bd, Isitman At

Open publisher page 6 citations

Abstract

While convenience and economy favor the use of in vivo methods for labeling red blood cells (RBCs) with [99mTc]pertechnetate, previous reports suggested that patient medication such as heparin might interfere and thus result in inferior quality images. In this study, using a canine model, the role of stannous Sn(II) ion in in vivo and in vitro labeling of RBCs both in the presence and absence of a therapeutic dose of heparin was investigated. Our results showed that Sn(II) ion concentration of 20 micrograms/kg body weight levels provided better than 80% in vivo labeling efficiency enabling high quality blood-pool images even in the presence of therapeutic doses of heparin.

About this research paper

What this paper is about

While convenience and economy favor the use of in vivo methods for labeling red blood cells (RBCs) with [99mTc]pertechnetate, previous reports suggested that patient medication such as heparin might interfere and thus result in inferior quality images. In this study, using a canine model, the role of stannous Sn(II) ion in in vivo and in vitro labeling of RBCs both in the presence and absence of a therapeutic dose of heparin was investigated. Our results showed that Sn(II) ion concentration of 20 micrograms/kg body weight levels provided better than 80% in vivo labeling efficiency enabling high quality blood-pool images even in the presence of therapeutic doses of heparin.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

While convenience and economy favor the use of in vivo methods for labeling red blood cells (RBCs) with [99mTc]pertechnetate, previous reports suggested that patient medication such as heparin might interfere and thus result in inferior quality images. In this study, using a canine model, the role of stannous Sn(II) ion in in vivo and in vitro labeling of RBCs both in the presence and absence of a therapeutic dose of heparin was investigated. Our results showed that Sn(II) ion concentration of 20 micrograms/kg body weight levels provided better than 80% in vivo labeling efficiency enabling high quality blood-pool images even in the presence of therapeutic doses of heparin.

Key concepts: Pertechnetate, In vivo, Heparin, Chemistry, Technetium-99m, Red blood cell, Technetium, In vitro

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of Sn(II) ion concentration and heparin on technetium-99m red blood cell labeling. — Research Paper | ScholarLens