1991PubMedRequires access

[Assessment of the MESAM and Biox 3700 early warning methods for the diagnosis of sleep-related respiratory disorders in young men].

B Hoch, Gregory Amend, U Mosebach, Thomas Penzel, J H Peter, Hartmut Schneider, P. v. Wichert

Open publisher page 0 citations

Abstract

We can use pulse oximetry as a method for diagnosis of the sleep apnoea syndrome, as well as L-EKG, MESAM II and the actigraph. In this study MESAM II and pulse oximetry were combined for finding out discrete sleep-related breathing disorders. The results were compared with polysomnography. 5 (15.1%) of 32 patients had an index of apnoea (AI) greater than 10, whereas 4 (12.1%) patients showed an AI greater than 5. All of the patients with positive signs in MESAM II/pulse oximetry had an AI greater than 5 in polysomnography, whereas non of the patients with negative signs in MESAM II/pulse oximetry had an AI greater than 5 in polysomnography.

About this research paper

What this paper is about

We can use pulse oximetry as a method for diagnosis of the sleep apnoea syndrome, as well as L-EKG, MESAM II and the actigraph. In this study MESAM II and pulse oximetry were combined for finding out discrete sleep-related breathing disorders. The results were compared with polysomnography. 5 (15.1%) of 32 patients had an index of apnoea (AI) greater than 10, whereas 4 (12.1%) patients showed an AI greater than 5. All of the patients with positive signs in MESAM II/pulse oximetry had an AI greater than 5 in polysomnography, whereas non of the patients with negative signs in MESAM II/pulse oximetry had an AI greater than 5 in polysomnography.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We can use pulse oximetry as a method for diagnosis of the sleep apnoea syndrome, as well as L-EKG, MESAM II and the actigraph. In this study MESAM II and pulse oximetry were combined for finding out discrete sleep-related breathing disorders. The results were compared with polysomnography. 5 (15.1%) of 32 patients had an index of apnoea (AI) greater than 10, whereas 4 (12.1%) patients showed an AI greater than 5. All of the patients with positive signs in MESAM II/pulse oximetry had an AI greater than 5 in polysomnography, whereas non of the patients with negative signs in MESAM II/pulse oximetry had an AI greater than 5 in polysomnography.

Key concepts: Polysomnography, Pulse oximetry, Medicine, Sleep (system call), Respiratory system, Internal medicine, Cardiology, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
[Assessment of the MESAM and Biox 3700 early warning methods for the diagnosis of sleep-related respiratory disorders in young men]. — Research Paper | ScholarLens