1995•PubMedRequires access

Comparison of two bolus doses of esmolol for attenuation of haemodynamic response to tracheal intubation.

S Sharma, Ghani Aa, Win N, Mudhasir Ahmad

Open publisher page 12 citations

Abstract

This prospective study was designed to compare the effectiveness of esmolol (either 100 mg or 200 mg) with a placebo in blunting the haemodynamic response to laryngoscopy and intubation. Seventy-five patients of ASA I or II scheduled for routine-surgery were selected and entered into a placebo-controlled study. Patients were randomly allocated to receive placebo, 100 mg or 200 mg of esmolol IV as part of an anaesthetic induction technique. There were no significant differences in the demographic distribution of the patients in the study. There was no statistical difference in the baseline heart rate (HR) and systolic blood pressure (SBP) between the three groups. One minute after the administration of the drug (prior to intubation) the differences in HR between the placebo group and both the 100 mg and 200 mg groups were significant (p < 0.05), and also at 1 min and 2 min following intubation for the 200 mg group (p < 0.05). In the 200 mg group there was a significant decrease, compared with placebo, in SBP at 1 min (p < 0.05) and at 2 min (p < 0.05) after intubation. In this study, adequate haemodynamic control following was obtained with the administration of 200 mg of esmolol.

About this research paper

What this paper is about

This prospective study was designed to compare the effectiveness of esmolol (either 100 mg or 200 mg) with a placebo in blunting the haemodynamic response to laryngoscopy and intubation. Seventy-five patients of ASA I or II scheduled for routine-surgery were selected and entered into a placebo-controlled study. Patients were randomly allocated to receive placebo, 100 mg or 200 mg of esmolol IV as part of an anaesthetic induction technique. There were no significant differences in the demographic distribution of the patients in the study. There was no statistical difference in the baseline heart rate (HR) and systolic blood pressure (SBP) between the three groups. One minute after the administration of the drug (prior to intubation) the differences in HR between the placebo group and both the 100 mg and 200 mg groups were significant (p < 0.05), and also at 1 min and 2 min following intubation for the 200 mg group (p < 0.05). In the 200 mg group there was a significant decrease, compared with placebo, in SBP at 1 min (p < 0.05) and at 2 min (p < 0.05) after intubation. In this study, adequate haemodynamic control following was obtained with the administration of 200 mg of esmolol.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This prospective study was designed to compare the effectiveness of esmolol (either 100 mg or 200 mg) with a placebo in blunting the haemodynamic response to laryngoscopy and intubation. Seventy-five patients of ASA I or II scheduled for routine-surgery were selected and entered into a placebo-controlled study. Patients were randomly allocated to receive placebo, 100 mg or 200 mg of esmolol IV as part of an anaesthetic induction technique. There were no significant differences in the demographic distribution of the patients in the study. There was no statistical difference in the baseline heart rate (HR) and systolic blood pressure (SBP) between the three groups. One minute after the administration of the drug (prior to intubation) the differences in HR between the placebo group and both the 100 mg and 200 mg groups were significant (p < 0.05), and also at 1 min and 2 min following intubation for the 200 mg group (p < 0.05). In the 200 mg group there was a significant decrease, compared with placebo, in SBP at 1 min (p < 0.05) and at 2 min (p < 0.05) after intubation. In this study, adequate haemodynamic control following was obtained with the administration of 200 mg of esmolol.

Key concepts: Esmolol, Medicine, Anesthesia, Intubation, Placebo, Laryngoscopy, Bolus (digestion), Hemodynamics

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of two bolus doses of esmolol for attenuation of haemodynamic response to tracheal intubation. — Research Paper | ScholarLens