2008•PubMedRequires access

Laparoscopic incisional hernia repair: our experience with 105 consecutive cases.

Fabrizio Ferranti, Giuseppe Passa, Alberto Stefanuto, Alberto Quintiliani

Open publisher page 2 citations

Abstract

Conventional repair of incisional hernia is associated with significant complications and a high recurrence rate (30-50%). The laparoscopic approach offers an effective alternative and reduces the recurrences to less than 5%. The aim of this study was to review our experience with laparoscopic incisional hernia repair. Medical records of all patients who underwent laparoscopic incisional hernia repair from January 2002 to December 2006 were reviewed. Demographic and postoperative data were recorded. The study population consisted of 105 patients, 72 females (68.5%) and 33 males (31.5%); the mean age was 56 years (range: 17-83 years). The mean fascial defect size was 116.9 cm2 and the average mesh size used was 256 cm2. Operative time was 118 min and the average hospital stay was 5 days. An expanded polytetrafluoroethylene (ePTFE) prosthesis was used In all patients. Perioperative complications occurred in 33 patients (31.4%) including seroma, cellulitis at the trocar site and prolonged ileus. During the follow-up there were 3 hernia recurrences (2.8%). Our study shows that laparoscopic incisional hernia repair resulted in a moderate rate of perioperative complications, a short hospital stay and a low recurrence rate. Hence the laparoscopic technique should be considered an effective and safe alternative to conventional incisional hernia repair.

About this research paper

What this paper is about

Conventional repair of incisional hernia is associated with significant complications and a high recurrence rate (30-50%). The laparoscopic approach offers an effective alternative and reduces the recurrences to less than 5%. The aim of this study was to review our experience with laparoscopic incisional hernia repair. Medical records of all patients who underwent laparoscopic incisional hernia repair from January 2002 to December 2006 were reviewed. Demographic and postoperative data were recorded. The study population consisted of 105 patients, 72 females (68.5%) and 33 males (31.5%); the mean age was 56 years (range: 17-83 years). The mean fascial defect size was 116.9 cm2 and the average mesh size used was 256 cm2. Operative time was 118 min and the average hospital stay was 5 days. An expanded polytetrafluoroethylene (ePTFE) prosthesis was used In all patients. Perioperative complications occurred in 33 patients (31.4%) including seroma, cellulitis at the trocar site and prolonged ileus. During the follow-up there were 3 hernia recurrences (2.8%). Our study shows that laparoscopic incisional hernia repair resulted in a moderate rate of perioperative complications, a short hospital stay and a low recurrence rate. Hence the laparoscopic technique should be considered an effective and safe alternative to conventional incisional hernia repair.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Conventional repair of incisional hernia is associated with significant complications and a high recurrence rate (30-50%). The laparoscopic approach offers an effective alternative and reduces the recurrences to less than 5%. The aim of this study was to review our experience with laparoscopic incisional hernia repair. Medical records of all patients who underwent laparoscopic incisional hernia repair from January 2002 to December 2006 were reviewed. Demographic and postoperative data were recorded. The study population consisted of 105 patients, 72 females (68.5%) and 33 males (31.5%); the mean age was 56 years (range: 17-83 years). The mean fascial defect size was 116.9 cm2 and the average mesh size used was 256 cm2. Operative time was 118 min and the average hospital stay was 5 days. An expanded polytetrafluoroethylene (ePTFE) prosthesis was used In all patients. Perioperative complications occurred in 33 patients (31.4%) including seroma, cellulitis at the trocar site and prolonged ileus. During the follow-up there were 3 hernia recurrences (2.8%). Our study shows that laparoscopic incisional hernia repair resulted in a moderate rate of perioperative complications, a short hospital stay and a low recurrence rate. Hence the laparoscopic technique should be considered an effective and safe alternative to conventional incisional hernia repair.

Key concepts: Medicine, Seroma, Incisional hernia, Surgery, Ileus, Perioperative, Hernia, Hernia repair

Related papers

Back to paper searchBrowse research topicsOriginal source
Laparoscopic incisional hernia repair: our experience with 105 consecutive cases. — Research Paper | ScholarLens