2003•Anaesthesia and Intensive CareOpen access

A Comparison of Four Intravenous Sedation Techniques and Bispectral Index Monitoring in Sinonasal Surgery

Ünase Büyükkoçak, S. Ozcan, Çağatay Daphan, Alpaslan Apan, Çetin Kaya Koç

Open full text 8 citations

Abstract

This study was performed to investigate the quality of different intravenous sedation techniques, and the correlation between the Bispectral Index (BIS) values and the Observer's Assessment of Alertness/Sedation (OAA/S) scores. Eighty patients undergoing sinonasal surgery were randomly assigned to one of four groups. Group MF received midazolam and fentanyl, group PF received propofol and fentanyl, group MR received midazolam and remifentanil, and group PR received propofol and remifentanil. Heart rate and mean arterial pressure values were not different among the groups. SpO2 decreased only after intravenous medication in groups MF and MR (P < 0.017). Emesis was less common with propofol. A positive relationship existed between the BIS values and OAA/S scores during the operation in all groups and the strongest correlation was observed in group PR (r = 0.565 and P < 0.001). In conclusion, these four intravenous sedation techniques did not change mean arterial pressure, heart rate or SpO2 clinically and produced a similar level of light sedation. The BIS was useful for monitoring of sedation during sinonasal surgery under local anaesthesia with intravenous sedation.

Open-access reader

About this research paper

What this paper is about

This study was performed to investigate the quality of different intravenous sedation techniques, and the correlation between the Bispectral Index (BIS) values and the Observer's Assessment of Alertness/Sedation (OAA/S) scores. Eighty patients undergoing sinonasal surgery were randomly assigned to one of four groups. Group MF received midazolam and fentanyl, group PF received propofol and fentanyl, group MR received midazolam and remifentanil, and group PR received propofol and remifentanil. Heart rate and mean arterial pressure values were not different among the groups. SpO2 decreased only after intravenous medication in groups MF and MR (P < 0.017). Emesis was less common with propofol. A positive relationship existed between the BIS values and OAA/S scores during the operation in all groups and the strongest correlation was observed in group PR (r = 0.565 and P < 0.001). In conclusion, these four intravenous sedation techniques did not change mean arterial pressure, heart rate or SpO2 clinically and produced a similar level of light sedation. The BIS was useful for monitoring of sedation during sinonasal surgery under local anaesthesia with intravenous sedation.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study was performed to investigate the quality of different intravenous sedation techniques, and the correlation between the Bispectral Index (BIS) values and the Observer's Assessment of Alertness/Sedation (OAA/S) scores. Eighty patients undergoing sinonasal surgery were randomly assigned to one of four groups. Group MF received midazolam and fentanyl, group PF received propofol and fentanyl, group MR received midazolam and remifentanil, and group PR received propofol and remifentanil. Heart rate and mean arterial pressure values were not different among the groups. SpO2 decreased only after intravenous medication in groups MF and MR (P < 0.017). Emesis was less common with propofol. A positive relationship existed between the BIS values and OAA/S scores during the operation in all groups and the strongest correlation was observed in group PR (r = 0.565 and P < 0.001). In conclusion, these four intravenous sedation techniques did not change mean arterial pressure, heart rate or SpO2 clinically and produced a similar level of light sedation. The BIS was useful for monitoring of sedation during sinonasal surgery under local anaesthesia with intravenous sedation.

Key concepts: Medicine, Bispectral index, Sedation, Intravenous sedation, Anesthesia, Propofol, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
A Comparison of Four Intravenous Sedation Techniques and Bispectral Index Monitoring in Sinonasal Surgery — Research Paper | ScholarLens