1989•PubMedRequires access

[Sensory action potentials of ring finger in the diagnosis of carpal tunnel syndrome].

Lin Jc, Chang Mk, Ting Ks

Open publisher page 0 citations

Abstract

Amplitudes and latencies of sensory action potentials (SAPs) recorded over the index, middle, little and ring fingers by antidromic stimulation of the median or ulnar nerve at wrist were measured in 65 normal adults and 78 patients with clinically and electrophysiologically verified carpal tunnel syndrome. In the normal adults, there was no significant difference among the SAP latencies of the index, middle, ring and little fingers. Among these 65 normal adults, the difference between median and ulnar SAPs of ring finger was less than 0.4 msec in 64 subjects, but 0.7 msec in one. In the patient group, the median distal sensory latency of the ring finger was significantly longer than that of the ulnar nerve which was recorded over the ring and little fingers. Six cases (7.7%) of 78 patients diagnosed as CTS by conventional electrophysiological studies was false negative by using the ring finger sensory action potential study. It is suggested that the SAP study of the ring finger by stimulation of the median and ulnar nerves at the wrist can not replace the conventional electrodiagnostic methods for the diagnosis of carpal tunnel syndrome.

About this research paper

What this paper is about

Amplitudes and latencies of sensory action potentials (SAPs) recorded over the index, middle, little and ring fingers by antidromic stimulation of the median or ulnar nerve at wrist were measured in 65 normal adults and 78 patients with clinically and electrophysiologically verified carpal tunnel syndrome. In the normal adults, there was no significant difference among the SAP latencies of the index, middle, ring and little fingers. Among these 65 normal adults, the difference between median and ulnar SAPs of ring finger was less than 0.4 msec in 64 subjects, but 0.7 msec in one. In the patient group, the median distal sensory latency of the ring finger was significantly longer than that of the ulnar nerve which was recorded over the ring and little fingers. Six cases (7.7%) of 78 patients diagnosed as CTS by conventional electrophysiological studies was false negative by using the ring finger sensory action potential study. It is suggested that the SAP study of the ring finger by stimulation of the median and ulnar nerves at the wrist can not replace the conventional electrodiagnostic methods for the diagnosis of carpal tunnel syndrome.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Amplitudes and latencies of sensory action potentials (SAPs) recorded over the index, middle, little and ring fingers by antidromic stimulation of the median or ulnar nerve at wrist were measured in 65 normal adults and 78 patients with clinically and electrophysiologically verified carpal tunnel syndrome. In the normal adults, there was no significant difference among the SAP latencies of the index, middle, ring and little fingers. Among these 65 normal adults, the difference between median and ulnar SAPs of ring finger was less than 0.4 msec in 64 subjects, but 0.7 msec in one. In the patient group, the median distal sensory latency of the ring finger was significantly longer than that of the ulnar nerve which was recorded over the ring and little fingers. Six cases (7.7%) of 78 patients diagnosed as CTS by conventional electrophysiological studies was false negative by using the ring finger sensory action potential study. It is suggested that the SAP study of the ring finger by stimulation of the median and ulnar nerves at the wrist can not replace the conventional electrodiagnostic methods for the diagnosis of carpal tunnel syndrome.

Key concepts: Carpal tunnel syndrome, Antidromic, Medicine, Ring finger, Wrist, Index finger, Ulnar nerve, Little finger

Related papers

Back to paper searchBrowse research topicsOriginal source
[Sensory action potentials of ring finger in the diagnosis of carpal tunnel syndrome]. — Research Paper | ScholarLens