2007PubMedRequires access

[Effect of dexmedetomidine on hemodynamics in pediatric patients following cardiac surgery].

Fuminori Tobise, Yuki Toyosmima, Shin Kawana

Open publisher page 3 citations

Abstract

BACKGROUND: Dexmedetomidine (DEX), a highly selective alpha2-adrenergic receptor agonist, has sedative and analgesic properties with minimal respiratory depression. We retrospectively evaluated the hemodynamic effects of dexmedetomidine in pediatric patients following cardiac surgery. METHODS: The subjects were twenty children aged 4 months to 15 years who had undergone cardiac surgery. After hemodynamics were stabilized in ICU, DEX was infused at a rate of 0.3-0.5 microg x kg(-1) min(-1), following initial loading (0.5 microg x kg(-1) over 10 min). Heart rate and blood pressure were analyzed just before starting infusion, following 1, 3, 6 hours during infusion, and at the end of the infusion. RESULTS: There was no change in blood pressure during measurement. HR was slightly decreased during DEX infusion but not significantly. After discontinuation of DEX, HR was significantly increased from 109 +/- 17 to 124 +/- 19 beats x min(-1) (mean +/- SD) (P < 0.05). Two patients were excluded from the study, because clinically significant bradycardia developed during DEX infusion. CONCLUSIONS: DEX had little effect on blood pressure in patients after cardiac surgery. DEX, however, had a tendency to decrease HR. Therefore, it shoud be used with caution in patients with low heart rate.

About this research paper

What this paper is about

BACKGROUND: Dexmedetomidine (DEX), a highly selective alpha2-adrenergic receptor agonist, has sedative and analgesic properties with minimal respiratory depression. We retrospectively evaluated the hemodynamic effects of dexmedetomidine in pediatric patients following cardiac surgery. METHODS: The subjects were twenty children aged 4 months to 15 years who had undergone cardiac surgery. After hemodynamics were stabilized in ICU, DEX was infused at a rate of 0.3-0.5 microg x kg(-1) min(-1), following initial loading (0.5 microg x kg(-1) over 10 min). Heart rate and blood pressure were analyzed just before starting infusion, following 1, 3, 6 hours during infusion, and at the end of the infusion. RESULTS: There was no change in blood pressure during measurement. HR was slightly decreased during DEX infusion but not significantly. After discontinuation of DEX, HR was significantly increased from 109 +/- 17 to 124 +/- 19 beats x min(-1) (mean +/- SD) (P < 0.05). Two patients were excluded from the study, because clinically significant bradycardia developed during DEX infusion. CONCLUSIONS: DEX had little effect on blood pressure in patients after cardiac surgery. DEX, however, had a tendency to decrease HR. Therefore, it shoud be used with caution in patients with low heart rate.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Dexmedetomidine (DEX), a highly selective alpha2-adrenergic receptor agonist, has sedative and analgesic properties with minimal respiratory depression. We retrospectively evaluated the hemodynamic effects of dexmedetomidine in pediatric patients following cardiac surgery. METHODS: The subjects were twenty children aged 4 months to 15 years who had undergone cardiac surgery. After hemodynamics were stabilized in ICU, DEX was infused at a rate of 0.3-0.5 microg x kg(-1) min(-1), following initial loading (0.5 microg x kg(-1) over 10 min). Heart rate and blood pressure were analyzed just before starting infusion, following 1, 3, 6 hours during infusion, and at the end of the infusion. RESULTS: There was no change in blood pressure during measurement. HR was slightly decreased during DEX infusion but not significantly. After discontinuation of DEX, HR was significantly increased from 109 +/- 17 to 124 +/- 19 beats x min(-1) (mean +/- SD) (P < 0.05). Two patients were excluded from the study, because clinically significant bradycardia developed during DEX infusion. CONCLUSIONS: DEX had little effect on blood pressure in patients after cardiac surgery. DEX, however, had a tendency to decrease HR. Therefore, it shoud be used with caution in patients with low heart rate.

Key concepts: Dexmedetomidine, Medicine, Hemodynamics, Anesthesia, Heart rate, Bradycardia, Blood pressure, Discontinuation

Related papers

Back to paper searchBrowse research topicsOriginal source
[Effect of dexmedetomidine on hemodynamics in pediatric patients following cardiac surgery]. — Research Paper | ScholarLens