2012PubMedRequires access

[Effects of sulphur compounds on the volatile characteristics of heavy metals in fly ash from the MSW and sewage sludge co-combustion plant during the disposal process with higher temperature].

Jingyong Liu, Shuiyu Sun

Open publisher page 3 citations

Abstract

Fly ash sample was collected from a MSW co-combustion with sewage sludge plant and the volatilization of heavy metals Pb, Cd, Cu and Zn was investigated before and after the water washing of fly ash, meanwhile, the influence of adding different sulphur compounds (S, NaS, Na2 SO3, Na2 SO4) on the volatilization of heavy metals was studied. The results showed that the contents of Zn, Pb and Mn were high, the Ni content was low and the Cd content reached 29.4 mg x kg(1). The contents of Pb, Cu, Zn increased, while that of Cd reduced in the fly ash after water washing. TG-DTG curves of fly ash showed highest weight loss in ranges of 579-732 degrees C and 949-1 200 degrees C, with 690 degrees C and 1 154 degrees C as the inflection point temperatures. The volatilization of different heavy metals showed great difference in the volatilization rate, following the order of Pb > Cd > Zn > Cu, in which the volatilization rate of Pb was more than 80% and that of Cu was less than 30%. After water washing, the volatilization of different heavy metals showed great difference in the volatilization rate, with the order of Zn > Pb > Cd > Cu, in which the volatilization rate of Zn was more than 20%. With the pretreatment of adding Na2 SO3 and Na2 SO4, the evaporation rates of heavy metals (Cu, Pb, Zn, Cd) were significantly decreased. After adding S, the evaporation rate of Zn was reduced, whereas the addition of Na2S reduced the evaporation rates of Cd and Zn. The evaporation rates of the four heavy metals were all reduced after adding Na2S in the washed fly ash. The evaporation rates of Cu and Zn were reduced with addition of S and Na2SO3 and the evaporation rate of Cd was reduced by adding the four sulfides. The results can provide a basis for the harmless disposal and maximized resource utilization and recycling of fly ash.

About this research paper

What this paper is about

Fly ash sample was collected from a MSW co-combustion with sewage sludge plant and the volatilization of heavy metals Pb, Cd, Cu and Zn was investigated before and after the water washing of fly ash, meanwhile, the influence of adding different sulphur compounds (S, NaS, Na2 SO3, Na2 SO4) on the volatilization of heavy metals was studied. The results showed that the contents of Zn, Pb and Mn were high, the Ni content was low and the Cd content reached 29.4 mg x kg(1). The contents of Pb, Cu, Zn increased, while that of Cd reduced in the fly ash after water washing. TG-DTG curves of fly ash showed highest weight loss in ranges of 579-732 degrees C and 949-1 200 degrees C, with 690 degrees C and 1 154 degrees C as the inflection point temperatures. The volatilization of different heavy metals showed great difference in the volatilization rate, following the order of Pb > Cd > Zn > Cu, in which the volatilization rate of Pb was more than 80% and that of Cu was less than 30%. After water washing, the volatilization of different heavy metals showed great difference in the volatilization rate, with the order of Zn > Pb > Cd > Cu, in which the volatilization rate of Zn was more than 20%. With the pretreatment of adding Na2 SO3 and Na2 SO4, the evaporation rates of heavy metals (Cu, Pb, Zn, Cd) were significantly decreased. After adding S, the evaporation rate of Zn was reduced, whereas the addition of Na2S reduced the evaporation rates of Cd and Zn. The evaporation rates of the four heavy metals were all reduced after adding Na2S in the washed fly ash. The evaporation rates of Cu and Zn were reduced with addition of S and Na2SO3 and the evaporation rate of Cd was reduced by adding the four sulfides. The results can provide a basis for the harmless disposal and maximized resource utilization and recycling of fly ash.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Fly ash sample was collected from a MSW co-combustion with sewage sludge plant and the volatilization of heavy metals Pb, Cd, Cu and Zn was investigated before and after the water washing of fly ash, meanwhile, the influence of adding different sulphur compounds (S, NaS, Na2 SO3, Na2 SO4) on the volatilization of heavy metals was studied. The results showed that the contents of Zn, Pb and Mn were high, the Ni content was low and the Cd content reached 29.4 mg x kg(1). The contents of Pb, Cu, Zn increased, while that of Cd reduced in the fly ash after water washing. TG-DTG curves of fly ash showed highest weight loss in ranges of 579-732 degrees C and 949-1 200 degrees C, with 690 degrees C and 1 154 degrees C as the inflection point temperatures. The volatilization of different heavy metals showed great difference in the volatilization rate, following the order of Pb > Cd > Zn > Cu, in which the volatilization rate of Pb was more than 80% and that of Cu was less than 30%. After water washing, the volatilization of different heavy metals showed great difference in the volatilization rate, with the order of Zn > Pb > Cd > Cu, in which the volatilization rate of Zn was more than 20%. With the pretreatment of adding Na2 SO3 and Na2 SO4, the evaporation rates of heavy metals (Cu, Pb, Zn, Cd) were significantly decreased. After adding S, the evaporation rate of Zn was reduced, whereas the addition of Na2S reduced the evaporation rates of Cd and Zn. The evaporation rates of the four heavy metals were all reduced after adding Na2S in the washed fly ash. The evaporation rates of Cu and Zn were reduced with addition of S and Na2SO3 and the evaporation rate of Cd was reduced by adding the four sulfides. The results can provide a basis for the harmless disposal and maximized resource utilization and recycling of fly ash.

Key concepts: Volatilisation, Fly ash, Chemistry, Environmental chemistry, Sewage sludge, Cadmium, Combustion, Heavy metals

Related papers

Back to paper searchBrowse research topicsOriginal source
[Effects of sulphur compounds on the volatile characteristics of heavy metals in fly ash from the MSW and sewage sludge co-combustion plant during the disposal process with higher temperature]. — Research Paper | ScholarLens