2016Journal of ProsthodonticsRequires access

Management of a Damaged Implant for Retention of an Overdenture Prosthesis and Fixed Single Crown: Clinical Reports

Paul A. Hansen, Arturo A. Salinas

Open publisher page 4 citations

Abstract

This article demonstrates a method to salvage an implant that has been damaged or is no longer usable because of a fractured screw that cannot be removed. In the first situation the patient had a Locator abutment that fractured during torqueing of the abutment. Despite the attempt to remove the fractured screw, it was not retrievable, and the internal threads of the implant were damaged in the attempt to remove the screw. Rather than removing the implant or covering it and sleeping the implant, a custom cast post was used to restore the implant to function. A second example describes a patient with a fixed implant crown. The implant was damaged during attempts to remove the fractured screw. A custom post was fabricated and cemented, and a new crown was fabricated.

About this research paper

What this paper is about

This article demonstrates a method to salvage an implant that has been damaged or is no longer usable because of a fractured screw that cannot be removed. In the first situation the patient had a Locator abutment that fractured during torqueing of the abutment. Despite the attempt to remove the fractured screw, it was not retrievable, and the internal threads of the implant were damaged in the attempt to remove the screw. Rather than removing the implant or covering it and sleeping the implant, a custom cast post was used to restore the implant to function. A second example describes a patient with a fixed implant crown. The implant was damaged during attempts to remove the fractured screw. A custom post was fabricated and cemented, and a new crown was fabricated.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This article demonstrates a method to salvage an implant that has been damaged or is no longer usable because of a fractured screw that cannot be removed. In the first situation the patient had a Locator abutment that fractured during torqueing of the abutment. Despite the attempt to remove the fractured screw, it was not retrievable, and the internal threads of the implant were damaged in the attempt to remove the screw. Rather than removing the implant or covering it and sleeping the implant, a custom cast post was used to restore the implant to function. A second example describes a patient with a fixed implant crown. The implant was damaged during attempts to remove the fractured screw. A custom post was fabricated and cemented, and a new crown was fabricated.

Key concepts: Crown (dentistry), Abutment, Implant, Dentistry, Dental Abutments, Prosthesis, Dental prosthesis, USable

Related papers

Back to paper searchBrowse research topicsOriginal source
Management of a Damaged Implant for Retention of an Overdenture Prosthesis and Fixed Single Crown: Clinical Reports — Research Paper | ScholarLens