1998PubMedRequires access

Response to inhaled nitric oxide in persistent pulmonary hypertension of the newborn: relationship to baseline oxygenation.

Parker Ta, Kinsella Jp, Abman Sh

Open publisher page 6 citations

Abstract

OBJECTIVE: We hypothesized that the magnitude of response to inhaled nitric oxide in persistent pulmonary hypertension of the newborn would correlate with the degree of baseline hypoxemia. STUDY DESIGN: We performed a retrospective chart review of 15 consecutive newborn infants with persistent pulmonary hypertension of the newborn treated with inhaled nitric oxide as part of a pilot study. Oxygenation index was calculated for each patient at baseline and 0.5 and 24 hours after the start of therapy and findings were compared by repeated-measures analysis of variance. Correlation was determined between baseline oxygenation index and 24-hour change in oxygenation index. RESULTS: Patients had a rapid and sustained decrease in oxygenation index (66.7 +/- 14.8 vs 26.3 +/- 5.0 vs 12.9 +/- 2.8, baseline vs 0.5 hour vs 24 hours; p < 0.001) during the study period, and the change in oxygenation index was highly correlated with baseline oxygenation index (r2 = 0.98). Two patients were placed on extracorporeal membrane oxygenation support before the 24-hour time point because of overwhelming sepsis and severe cardiac dysfunction. CONCLUSIONS: In patients with severe persistent pulmonary hypertension of the newborn, we conclude that the clinical response to inhaled nitric oxide is most dramatic in those patients with the most severe hypoxemia.

About this research paper

What this paper is about

OBJECTIVE: We hypothesized that the magnitude of response to inhaled nitric oxide in persistent pulmonary hypertension of the newborn would correlate with the degree of baseline hypoxemia. STUDY DESIGN: We performed a retrospective chart review of 15 consecutive newborn infants with persistent pulmonary hypertension of the newborn treated with inhaled nitric oxide as part of a pilot study. Oxygenation index was calculated for each patient at baseline and 0.5 and 24 hours after the start of therapy and findings were compared by repeated-measures analysis of variance. Correlation was determined between baseline oxygenation index and 24-hour change in oxygenation index. RESULTS: Patients had a rapid and sustained decrease in oxygenation index (66.7 +/- 14.8 vs 26.3 +/- 5.0 vs 12.9 +/- 2.8, baseline vs 0.5 hour vs 24 hours; p < 0.001) during the study period, and the change in oxygenation index was highly correlated with baseline oxygenation index (r2 = 0.98). Two patients were placed on extracorporeal membrane oxygenation support before the 24-hour time point because of overwhelming sepsis and severe cardiac dysfunction. CONCLUSIONS: In patients with severe persistent pulmonary hypertension of the newborn, we conclude that the clinical response to inhaled nitric oxide is most dramatic in those patients with the most severe hypoxemia.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: We hypothesized that the magnitude of response to inhaled nitric oxide in persistent pulmonary hypertension of the newborn would correlate with the degree of baseline hypoxemia. STUDY DESIGN: We performed a retrospective chart review of 15 consecutive newborn infants with persistent pulmonary hypertension of the newborn treated with inhaled nitric oxide as part of a pilot study. Oxygenation index was calculated for each patient at baseline and 0.5 and 24 hours after the start of therapy and findings were compared by repeated-measures analysis of variance. Correlation was determined between baseline oxygenation index and 24-hour change in oxygenation index. RESULTS: Patients had a rapid and sustained decrease in oxygenation index (66.7 +/- 14.8 vs 26.3 +/- 5.0 vs 12.9 +/- 2.8, baseline vs 0.5 hour vs 24 hours; p < 0.001) during the study period, and the change in oxygenation index was highly correlated with baseline oxygenation index (r2 = 0.98). Two patients were placed on extracorporeal membrane oxygenation support before the 24-hour time point because of overwhelming sepsis and severe cardiac dysfunction. CONCLUSIONS: In patients with severe persistent pulmonary hypertension of the newborn, we conclude that the clinical response to inhaled nitric oxide is most dramatic in those patients with the most severe hypoxemia.

Key concepts: Oxygenation index, Medicine, Oxygenation, Extracorporeal membrane oxygenation, Hypoxemia, Nitric oxide, Anesthesia, Pulmonary hypertension

Related papers

Back to paper searchBrowse research topicsOriginal source
Response to inhaled nitric oxide in persistent pulmonary hypertension of the newborn: relationship to baseline oxygenation. — Research Paper | ScholarLens