2016HypertensionOpen access

Efficacy of Servo-Controlled Splanchnic Venous Compression in the Treatment of Orthostatic Hypotension

Luis E. Okamoto, André Diedrich, Franz J. Baudenbacher, René Harder, Jonathan S. Whitfield, Fahad Mujtaba Iqbal, Alfredo C. Gamboa, Cyndya A. Shibao, Bonnie K. Black, Satish R. Raj, David Robertson, Italo Biaggioni

Open full text 78 citations

Abstract

UNLABELLED: Splanchnic venous pooling is a major hemodynamic determinant of orthostatic hypotension, but is not specifically targeted by pressor agents, the mainstay of treatment. We developed an automated inflatable abdominal binder that provides sustained servo-controlled venous compression (40 mm Hg) and can be activated only on standing. We tested the efficacy of this device against placebo and compared it to midodrine in 19 autonomic failure patients randomized to receive either placebo, midodrine (2.5-10 mg), or placebo combined with binder on separate days in a single-blind, crossover study. Systolic blood pressure (SBP) was measured seated and standing before and 1-hour post medication; the binder was inflated immediately before standing. Only midodrine increased seated SBP (31±5 versus 9±4 placebo and 7±5 binder, P=0.003), whereas orthostatic tolerance (defined as area under the curve of upright SBP [AUCSBP]) improved similarly with binder and midodrine (AUCSBP, 195±35 and 197±41 versus 19±38 mm Hg×minute for placebo; P=0.003). Orthostatic symptom burden decreased with the binder (from 21.9±3.6 to 16.3±3.1, P=0.032) and midodrine (from 25.6±3.4 to 14.2±3.3, P<0.001), but not with placebo (from 19.6±3.5 to 20.1±3.3, P=0.756). We also compared the combination of midodrine and binder with midodrine alone. The combination produced a greater increase in orthostatic tolerance (AUCSBP, 326±65 versus 140±53 mm Hg×minute for midodrine alone; P=0.028, n=21) and decreased orthostatic symptoms (from 21.8±3.2 to 12.9±2.9, P<0.001). In conclusion, servo-controlled abdominal venous compression with an automated inflatable binder is as effective as midodrine, the standard of care, in the management of orthostatic hypotension. Combining both therapies produces greater improvement in orthostatic tolerance. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00223691.

Open-access reader

About this research paper

What this paper is about

UNLABELLED: Splanchnic venous pooling is a major hemodynamic determinant of orthostatic hypotension, but is not specifically targeted by pressor agents, the mainstay of treatment. We developed an automated inflatable abdominal binder that provides sustained servo-controlled venous compression (40 mm Hg) and can be activated only on standing. We tested the efficacy of this device against placebo and compared it to midodrine in 19 autonomic failure patients randomized to receive either placebo, midodrine (2.5-10 mg), or placebo combined with binder on separate days in a single-blind, crossover study. Systolic blood pressure (SBP) was measured seated and standing before and 1-hour post medication; the binder was inflated immediately before standing. Only midodrine increased seated SBP (31±5 versus 9±4 placebo and 7±5 binder, P=0.003), whereas orthostatic tolerance (defined as area under the curve of upright SBP [AUCSBP]) improved similarly with binder and midodrine (AUCSBP, 195±35 and 197±41 versus 19±38 mm Hg×minute for placebo; P=0.003). Orthostatic symptom burden decreased with the binder (from 21.9±3.6 to 16.3±3.1, P=0.032) and midodrine (from 25.6±3.4 to 14.2±3.3, P<0.001), but not with placebo (from 19.6±3.5 to 20.1±3.3, P=0.756). We also compared the combination of midodrine and binder with midodrine alone. The combination produced a greater increase in orthostatic tolerance (AUCSBP, 326±65 versus 140±53 mm Hg×minute for midodrine alone; P=0.028, n=21) and decreased orthostatic symptoms (from 21.8±3.2 to 12.9±2.9, P<0.001). In conclusion, servo-controlled abdominal venous compression with an automated inflatable binder is as effective as midodrine, the standard of care, in the management of orthostatic hypotension. Combining both therapies produces greater improvement in orthostatic tolerance. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00223691.

Why it matters

OpenAlex reports 78 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

UNLABELLED: Splanchnic venous pooling is a major hemodynamic determinant of orthostatic hypotension, but is not specifically targeted by pressor agents, the mainstay of treatment. We developed an automated inflatable abdominal binder that provides sustained servo-controlled venous compression (40 mm Hg) and can be activated only on standing. We tested the efficacy of this device against placebo and compared it to midodrine in 19 autonomic failure patients randomized to receive either placebo, midodrine (2.5-10 mg), or placebo combined with binder on separate days in a single-blind, crossover study. Systolic blood pressure (SBP) was measured seated and standing before and 1-hour post medication; the binder was inflated immediately before standing. Only midodrine increased seated SBP (31±5 versus 9±4 placebo and 7±5 binder, P=0.003), whereas orthostatic tolerance (defined as area under the curve of upright SBP [AUCSBP]) improved similarly with binder and midodrine (AUCSBP, 195±35 and 197±41 versus 19±38 mm Hg×minute for placebo; P=0.003). Orthostatic symptom burden decreased with the binder (from 21.9±3.6 to 16.3±3.1, P=0.032) and midodrine (from 25.6±3.4 to 14.2±3.3, P<0.001), but not with placebo (from 19.6±3.5 to 20.1±3.3, P=0.756). We also compared the combination of midodrine and binder with midodrine alone. The combination produced a greater increase in orthostatic tolerance (AUCSBP, 326±65 versus 140±53 mm Hg×minute for midodrine alone; P=0.028, n=21) and decreased orthostatic symptoms (from 21.8±3.2 to 12.9±2.9, P<0.001). In conclusion, servo-controlled abdominal venous compression with an automated inflatable binder is as effective as midodrine, the standard of care, in the management of orthostatic hypotension. Combining both therapies produces greater improvement in orthostatic tolerance. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00223691.

Key concepts: Midodrine, Orthostatic vital signs, Medicine, Placebo, Pure autonomic failure, Anesthesia, Blood pressure, Splanchnic

Related papers

Back to paper searchBrowse research topicsOriginal source
Efficacy of Servo-Controlled Splanchnic Venous Compression in the Treatment of Orthostatic Hypotension — Research Paper | ScholarLens