2000PubMedRequires access

[Heparin monitoring during cardiopulmonary bypass in congenital heart surgery].

Yukihisa Isomatsu, Y Imai, K Seo, M Terada, Marcelo Saldanha Aoki, T Shin'oka

Open publisher page 1 citations

Abstract

The Hepcon/HMS system automatically provides the activated clotting time and a whole blood heparin concentration. It also provides the adequate protamine dose by titration of protamine to heparin. 45 patients undergoing congenital heart surgery with cardiopulmonary bypass (CPB) were studied by the Hepcon/HMS device. We measured the heparin dose response before heparin administration, and the ration between the dose of protamine (ml) which was necessary for heparin neutralization at the termination of CPB and the dose of total heparin (ml) in each patient. The value of heparin dose response ranged 120-390 (mean 228) IU/kg. The ratio between protamine dose and heparin dose varied 0.11-0.99 (mean 0.55). There was a statistically significant correlation between the duration of CPB and this ratio (r = -0.51, n = 45, p = 0.0005). From the standpoint of variances in the value of heparin dose response, conventional way of the heparin administration according to the patient's body weight alone may cause inadequacy of anticoagulation during CPB. A dose of protamine determined by Hepcon device that is smaller than a conventional dose of protamine prevents inadvertent overdose and, therefore, can reduce the adverse effects excessive protamine has.

About this research paper

What this paper is about

The Hepcon/HMS system automatically provides the activated clotting time and a whole blood heparin concentration. It also provides the adequate protamine dose by titration of protamine to heparin. 45 patients undergoing congenital heart surgery with cardiopulmonary bypass (CPB) were studied by the Hepcon/HMS device. We measured the heparin dose response before heparin administration, and the ration between the dose of protamine (ml) which was necessary for heparin neutralization at the termination of CPB and the dose of total heparin (ml) in each patient. The value of heparin dose response ranged 120-390 (mean 228) IU/kg. The ratio between protamine dose and heparin dose varied 0.11-0.99 (mean 0.55). There was a statistically significant correlation between the duration of CPB and this ratio (r = -0.51, n = 45, p = 0.0005). From the standpoint of variances in the value of heparin dose response, conventional way of the heparin administration according to the patient's body weight alone may cause inadequacy of anticoagulation during CPB. A dose of protamine determined by Hepcon device that is smaller than a conventional dose of protamine prevents inadvertent overdose and, therefore, can reduce the adverse effects excessive protamine has.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The Hepcon/HMS system automatically provides the activated clotting time and a whole blood heparin concentration. It also provides the adequate protamine dose by titration of protamine to heparin. 45 patients undergoing congenital heart surgery with cardiopulmonary bypass (CPB) were studied by the Hepcon/HMS device. We measured the heparin dose response before heparin administration, and the ration between the dose of protamine (ml) which was necessary for heparin neutralization at the termination of CPB and the dose of total heparin (ml) in each patient. The value of heparin dose response ranged 120-390 (mean 228) IU/kg. The ratio between protamine dose and heparin dose varied 0.11-0.99 (mean 0.55). There was a statistically significant correlation between the duration of CPB and this ratio (r = -0.51, n = 45, p = 0.0005). From the standpoint of variances in the value of heparin dose response, conventional way of the heparin administration according to the patient's body weight alone may cause inadequacy of anticoagulation during CPB. A dose of protamine determined by Hepcon device that is smaller than a conventional dose of protamine prevents inadvertent overdose and, therefore, can reduce the adverse effects excessive protamine has.

Key concepts: Protamine, Heparin, Cardiopulmonary bypass, Activated clotting time, Medicine, Anesthesia, Anticoagulant, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
[Heparin monitoring during cardiopulmonary bypass in congenital heart surgery]. — Research Paper | ScholarLens