The article deals with rapid agglutination tests for Staphylococcus aureus identification which detect clumping factor and protein A. The tests were compared with standard diagnostic methods: free coagulase, bound coagulase and thermostable deoxyribonuclease, 190 Staphylococcus aureus strains have been examined of which, 105 methicillin susceptible strains, 85 methicillin resistant strains, and 32 coagulase negative staphylococci strains strains. The presence of clumping factor was detected in 100% of examined Staphylococcus aureus strains. No difference between methicillin susceptible strains and methicillin resistant strains was observed. Protein A was present in 96.1% of methicillin susceptible strains and in 90.6% of methicillin resistant Staphylococcus aureus strains. The same test showed false negative results in 12 strains: 4 of which methicillin susceptible and 8 methicillin resistant strains. Coagulase test slide method and protein A detecting test hand one false positive result each for coagulase negative staphylococci examined. The specificity of all tests used was 100% and 99.5% respectively. The authors suggest latex or hemagglutination tests detecting clumping factor and/or protein A for rapid Staphylococcus aureus strains identification in hospital environment. It is important to point out the possibility of getting false negative protein A detecting results in methicillin resistant strains.

About this research paper

What this paper is about

The article deals with rapid agglutination tests for Staphylococcus aureus identification which detect clumping factor and protein A. The tests were compared with standard diagnostic methods: free coagulase, bound coagulase and thermostable deoxyribonuclease, 190 Staphylococcus aureus strains have been examined of which, 105 methicillin susceptible strains, 85 methicillin resistant strains, and 32 coagulase negative staphylococci strains strains. The presence of clumping factor was detected in 100% of examined Staphylococcus aureus strains. No difference between methicillin susceptible strains and methicillin resistant strains was observed. Protein A was present in 96.1% of methicillin susceptible strains and in 90.6% of methicillin resistant Staphylococcus aureus strains. The same test showed false negative results in 12 strains: 4 of which methicillin susceptible and 8 methicillin resistant strains. Coagulase test slide method and protein A detecting test hand one false positive result each for coagulase negative staphylococci examined. The specificity of all tests used was 100% and 99.5% respectively. The authors suggest latex or hemagglutination tests detecting clumping factor and/or protein A for rapid Staphylococcus aureus strains identification in hospital environment. It is important to point out the possibility of getting false negative protein A detecting results in methicillin resistant strains.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The article deals with rapid agglutination tests for Staphylococcus aureus identification which detect clumping factor and protein A. The tests were compared with standard diagnostic methods: free coagulase, bound coagulase and thermostable deoxyribonuclease, 190 Staphylococcus aureus strains have been examined of which, 105 methicillin susceptible strains, 85 methicillin resistant strains, and 32 coagulase negative staphylococci strains strains. The presence of clumping factor was detected in 100% of examined Staphylococcus aureus strains. No difference between methicillin susceptible strains and methicillin resistant strains was observed. Protein A was present in 96.1% of methicillin susceptible strains and in 90.6% of methicillin resistant Staphylococcus aureus strains. The same test showed false negative results in 12 strains: 4 of which methicillin susceptible and 8 methicillin resistant strains. Coagulase test slide method and protein A detecting test hand one false positive result each for coagulase negative staphylococci examined. The specificity of all tests used was 100% and 99.5% respectively. The authors suggest latex or hemagglutination tests detecting clumping factor and/or protein A for rapid Staphylococcus aureus strains identification in hospital environment. It is important to point out the possibility of getting false negative protein A detecting results in methicillin resistant strains.

Key concepts: Staphylococcus aureus, Coagulase, Microbiology, Latex fixation test, Medicine, Staphylococcus, Agglutination (biology), Deoxyribonuclease

Related papers

Back to paper searchBrowse research topicsOriginal source
[Rapid agglutination tests for the identification of Staphylococcus aureus]. — Research Paper | ScholarLens