1997PubMedRequires access

[Study on separating characteristics in capillary reversed-phase electrochromatography].

Wei Wei, Y Wang, G Luo

Open publisher page 0 citations

Abstract

Capillary Electrochromatography (CEC) driven by electroosmotic flow is a new technique using fused silica capillaries packed with HPLC-type stationary phase. The analytes are separated by normal chromatographic partition between a mobile phase and a stationary phase. By using electroosmotic flow driving mobile phase, CEC promises theoretical plate efficiencies for HPLC. In this paper, some separating characteristics in capillary electrochromatography were studied by carrying out the separation of some neutral compounds on capillary column with 75microm i.d. x 30cm/37cm packed with ODS particles (3microm). The mobile phase was acetonitrile and water, which contains certain concentration of electrolyte. Samples were injected electrokinetically into the separating column. On-line UV detector was used. The Joule heating effect in packed CEC was lower than that in CZE, and a good linear relationship between the elecrtoosmotic flow (EOF) velocity and applied voltage was obtained as shown in Fig. 1. The influence of electrolyte and acetonitrile concentrations on the electroosmotic flow was studied, as shown in Fig. 2 and 5. The EOF was monitored by using thiourea as a marker. The EOF will decrease when the electrolyte concentration increases. The higher the acetonitrile concentration was, the lower the EOF was. The effect of linear velocity on column efficiencies was also investigated. The column effeciencies less than 2. 0 reduced plate height were obtained. The highest efficiency obtained in this work was 236000 plate per meter for a retained solute, benzene. It was found that the concentrations of acetonitrile and electrolyte were important experimental variables in performance of capillary electrochromatography.

About this research paper

What this paper is about

Capillary Electrochromatography (CEC) driven by electroosmotic flow is a new technique using fused silica capillaries packed with HPLC-type stationary phase. The analytes are separated by normal chromatographic partition between a mobile phase and a stationary phase. By using electroosmotic flow driving mobile phase, CEC promises theoretical plate efficiencies for HPLC. In this paper, some separating characteristics in capillary electrochromatography were studied by carrying out the separation of some neutral compounds on capillary column with 75microm i.d. x 30cm/37cm packed with ODS particles (3microm). The mobile phase was acetonitrile and water, which contains certain concentration of electrolyte. Samples were injected electrokinetically into the separating column. On-line UV detector was used. The Joule heating effect in packed CEC was lower than that in CZE, and a good linear relationship between the elecrtoosmotic flow (EOF) velocity and applied voltage was obtained as shown in Fig. 1. The influence of electrolyte and acetonitrile concentrations on the electroosmotic flow was studied, as shown in Fig. 2 and 5. The EOF was monitored by using thiourea as a marker. The EOF will decrease when the electrolyte concentration increases. The higher the acetonitrile concentration was, the lower the EOF was. The effect of linear velocity on column efficiencies was also investigated. The column effeciencies less than 2. 0 reduced plate height were obtained. The highest efficiency obtained in this work was 236000 plate per meter for a retained solute, benzene. It was found that the concentrations of acetonitrile and electrolyte were important experimental variables in performance of capillary electrochromatography.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Capillary Electrochromatography (CEC) driven by electroosmotic flow is a new technique using fused silica capillaries packed with HPLC-type stationary phase. The analytes are separated by normal chromatographic partition between a mobile phase and a stationary phase. By using electroosmotic flow driving mobile phase, CEC promises theoretical plate efficiencies for HPLC. In this paper, some separating characteristics in capillary electrochromatography were studied by carrying out the separation of some neutral compounds on capillary column with 75microm i.d. x 30cm/37cm packed with ODS particles (3microm). The mobile phase was acetonitrile and water, which contains certain concentration of electrolyte. Samples were injected electrokinetically into the separating column. On-line UV detector was used. The Joule heating effect in packed CEC was lower than that in CZE, and a good linear relationship between the elecrtoosmotic flow (EOF) velocity and applied voltage was obtained as shown in Fig. 1. The influence of electrolyte and acetonitrile concentrations on the electroosmotic flow was studied, as shown in Fig. 2 and 5. The EOF was monitored by using thiourea as a marker. The EOF will decrease when the electrolyte concentration increases. The higher the acetonitrile concentration was, the lower the EOF was. The effect of linear velocity on column efficiencies was also investigated. The column effeciencies less than 2. 0 reduced plate height were obtained. The highest efficiency obtained in this work was 236000 plate per meter for a retained solute, benzene. It was found that the concentrations of acetonitrile and electrolyte were important experimental variables in performance of capillary electrochromatography.

Key concepts: Capillary electrochromatography, Electrochromatography, Electrolyte, Acetonitrile, Chromatography, Chemistry, Capillary action, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
[Study on separating characteristics in capillary reversed-phase electrochromatography]. — Research Paper | ScholarLens