1980PubMedRequires access

Distortions in the ECG caused by instruments for ambulatory electrocardiography.

Peter Bjerregaard

Open publisher page 4 citations

Abstract

The frequency response and speed stability of a widely used tape recorder (Oxford Medilog) and arrhythmia computer (Reynolds Pathfinder) was evaluated and measurement in time and amplitude on the ambulatory ECG compared with correspondent measurement in the conventional ECG. The overall bandwidth was 0.15--33Hz (3 dB down) and the mean speed error +2% +/- 1.8%. There was no statistically significant difference between P-Q and Q-T intervals measured by the 2 methods, but a significant reduction in wave amplitudes in the ambulatory ECG. The demarcation of QRS complexes was often blurred in the ambulatory ECG and borderline complexes difficult to classify as normal or abnormal on QRS width alone. Artifical J point depression was a common finding in the ambulatory ECT, whereas horizontal or downsloping ST segment depression was faithfully reproduced.

About this research paper

What this paper is about

The frequency response and speed stability of a widely used tape recorder (Oxford Medilog) and arrhythmia computer (Reynolds Pathfinder) was evaluated and measurement in time and amplitude on the ambulatory ECG compared with correspondent measurement in the conventional ECG. The overall bandwidth was 0.15--33Hz (3 dB down) and the mean speed error +2% +/- 1.8%. There was no statistically significant difference between P-Q and Q-T intervals measured by the 2 methods, but a significant reduction in wave amplitudes in the ambulatory ECG. The demarcation of QRS complexes was often blurred in the ambulatory ECG and borderline complexes difficult to classify as normal or abnormal on QRS width alone. Artifical J point depression was a common finding in the ambulatory ECT, whereas horizontal or downsloping ST segment depression was faithfully reproduced.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The frequency response and speed stability of a widely used tape recorder (Oxford Medilog) and arrhythmia computer (Reynolds Pathfinder) was evaluated and measurement in time and amplitude on the ambulatory ECG compared with correspondent measurement in the conventional ECG. The overall bandwidth was 0.15--33Hz (3 dB down) and the mean speed error +2% +/- 1.8%. There was no statistically significant difference between P-Q and Q-T intervals measured by the 2 methods, but a significant reduction in wave amplitudes in the ambulatory ECG. The demarcation of QRS complexes was often blurred in the ambulatory ECG and borderline complexes difficult to classify as normal or abnormal on QRS width alone. Artifical J point depression was a common finding in the ambulatory ECT, whereas horizontal or downsloping ST segment depression was faithfully reproduced.

Key concepts: Ambulatory, QRS complex, Electrocardiography, Cardiology, Medicine, Ambulatory ECG, ST segment, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Distortions in the ECG caused by instruments for ambulatory electrocardiography. — Research Paper | ScholarLens