1983PubMedRequires access

Removal of Harrington's distraction apparatus after vertebral arthrodesis.

F. Travaglini

Open publisher page 0 citations

Abstract

The author reviews 13 cases of vertebral arthrodesis for scoliosis, during the five years from 1977 to 1981, in which the Harrington distraction apparatus was removed. Contrary to opinions expressed in the literature, there were no technical difficulties or allied complications. Only in 4 cases was the arthrodesis area fully inspected, and then only to check the condition of the graft. In 9 cases the distraction apparatus was removed by a limited exposure of the extremities of the initial operation area.

About this research paper

What this paper is about

The author reviews 13 cases of vertebral arthrodesis for scoliosis, during the five years from 1977 to 1981, in which the Harrington distraction apparatus was removed. Contrary to opinions expressed in the literature, there were no technical difficulties or allied complications. Only in 4 cases was the arthrodesis area fully inspected, and then only to check the condition of the graft. In 9 cases the distraction apparatus was removed by a limited exposure of the extremities of the initial operation area.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The author reviews 13 cases of vertebral arthrodesis for scoliosis, during the five years from 1977 to 1981, in which the Harrington distraction apparatus was removed. Contrary to opinions expressed in the literature, there were no technical difficulties or allied complications. Only in 4 cases was the arthrodesis area fully inspected, and then only to check the condition of the graft. In 9 cases the distraction apparatus was removed by a limited exposure of the extremities of the initial operation area.

Key concepts: Medicine, Distraction, Arthrodesis, Scoliosis, Surgery, Orthodontics, Alternative medicine, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Removal of Harrington's distraction apparatus after vertebral arthrodesis. — Research Paper | ScholarLens