The Accuracy and Reliability of an Infusion Pump (STC-3121; Terumo Inst., Japan) during Hyperbaric Oxygenation

Hiroshi Dohgomori, K Arikawa, H. Kubo

Open full text 9 citations

Abstract

We evaluated the accuracy of delivery of one type of infusion pump at three nominal flow rates under two environmental pressures (measured in atmospheres absolute, ATA), one of which is used for hyperbaric oxygenation. Overall, we observed significant differences between the two different pressures (1 ATA and 2 ATA). Changes in the rate of delivery of between about -4% and +2% were observed over the time course of hyperbaric oxygenation, and the inter-group difference was significant in the phases in which pressure was changing. The effect produced by 2 ATA was statistically significant but small, and its influence is likely to be negligible during practical hyperbaric oxygenation therapy. Thus, it would seem that this type of pump would deliver reliably at the nominal rate during hyperbaric oxygenation at these levels.

Open-access reader

About this research paper

What this paper is about

We evaluated the accuracy of delivery of one type of infusion pump at three nominal flow rates under two environmental pressures (measured in atmospheres absolute, ATA), one of which is used for hyperbaric oxygenation. Overall, we observed significant differences between the two different pressures (1 ATA and 2 ATA). Changes in the rate of delivery of between about -4% and +2% were observed over the time course of hyperbaric oxygenation, and the inter-group difference was significant in the phases in which pressure was changing. The effect produced by 2 ATA was statistically significant but small, and its influence is likely to be negligible during practical hyperbaric oxygenation therapy. Thus, it would seem that this type of pump would deliver reliably at the nominal rate during hyperbaric oxygenation at these levels.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We evaluated the accuracy of delivery of one type of infusion pump at three nominal flow rates under two environmental pressures (measured in atmospheres absolute, ATA), one of which is used for hyperbaric oxygenation. Overall, we observed significant differences between the two different pressures (1 ATA and 2 ATA). Changes in the rate of delivery of between about -4% and +2% were observed over the time course of hyperbaric oxygenation, and the inter-group difference was significant in the phases in which pressure was changing. The effect produced by 2 ATA was statistically significant but small, and its influence is likely to be negligible during practical hyperbaric oxygenation therapy. Thus, it would seem that this type of pump would deliver reliably at the nominal rate during hyperbaric oxygenation at these levels.

Key concepts: Hyperbaric oxygenation, Medicine, Oxygenation, Anesthesia, Infusion pump, Hyperbaric oxygen

Related papers

Back to paper searchBrowse research topicsOriginal source
The Accuracy and Reliability of an Infusion Pump (STC-3121; Terumo Inst., Japan) during Hyperbaric Oxygenation — Research Paper | ScholarLens