Contrast testing for magnetic resonance imaging.
Anderson Dw, Yamanashi Ws, Stanley Dw, Wohler Jb
Abstract
Anderson Dw, Yamanashi Ws, Stanley Dw, Wohler Jb
Abstract
A test phantom for evaluating magnetic resonance image contrast was constructed using separate chambers filled with manganese chloride (MnCl2) solutions of different concentrations. The concentrations were chosen so that the relaxation times produced were distributed over the range appropriate for human tissues in brain imaging. Specific solutions had relaxation properties similar to those of white matter, gray matter, and brain tumors. The region surrounding the chambers was filled with a sodium chloride solution with conductivity similar to that of brain tissue so that radiofrequency signal absorption would be appropriate. When magnetic resonance relaxation response curves were obtained with the phantom, relaxation contrast and latitude could be compared for different imaging pulse sequences. Contrast responses for gradient echo sequences differed considerably when the flip angle was changed.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A test phantom for evaluating magnetic resonance image contrast was constructed using separate chambers filled with manganese chloride (MnCl2) solutions of different concentrations. The concentrations were chosen so that the relaxation times produced were distributed over the range appropriate for human tissues in brain imaging. Specific solutions had relaxation properties similar to those of white matter, gray matter, and brain tumors. The region surrounding the chambers was filled with a sodium chloride solution with conductivity similar to that of brain tissue so that radiofrequency signal absorption would be appropriate. When magnetic resonance relaxation response curves were obtained with the phantom, relaxation contrast and latitude could be compared for different imaging pulse sequences. Contrast responses for gradient echo sequences differed considerably when the flip angle was changed.
Key concepts: Imaging phantom, Magnetic resonance imaging, Contrast (vision), Nuclear magnetic resonance, Relaxation (psychology), White matter, Spin–lattice relaxation, Materials science