2011PubMedRequires access

[Analysis of the 1000 Hz tympanometry in normal hearing neonates].

Jinshan Lu, Zhang Jin, Liang Tang, Wei Ding, Lun Zhang, Xiaoping Guo, Nu-la Zai

Open publisher page 0 citations

Abstract

OBJECTIVE: To analysis the clinical characteristics of 1000 Hz probe tone tympanometry obtained from normal neonates who passed the OAE screening. To calculate the normal range of the variances of the tympanometry, which may serve as the guide for newborn hearing screening and detect middle ear function in neonates. METHODS: OAE screening were performed to screen the hearing with GSI-70 Automated OAE. The 1000 Hz probe tone tympanograms were obtained from 650 neonates who passed the TEOAE screening in both ears and were on the normal physiological conditions after birth with GSI Tympstar Version II Middle Ear Analyzer. The means, the standard deviation, the 95% confidence interval were analyzed. RESULTS: The 1000 Hz tympanometric data showed the 1Y1B1G tympanogram in 732 ears (56.3%), the 1Y3B1G tympanogram in 145 ears (11.2%), the 0Y0B0G tympanogram in 269 ears (20.7%), other shapes in 154 ears (11.8%) according to the Vanhuyse model. The 1000 Hz tympanometric datas showed the single-peaked tympanogram in 967 ears, the 95% confidence interval of the tympanometric data were as follows: tympanometric peak pressure (Tpp) was from -55.0 to 180.0 daPa, peak compensated static acoustic admittance (Peak Ytm) was 0.03-1.18 mmHo, tympanometric width (TW) was 70.0-230.0 daPa. CONCLUSIONS: The majority of 1000 Hz tympanograms from this study show the single-peaked in normal neonates. The 95% confidence interval of the tympanometric data may serve as a guide for hearing screening and detecting middle ear function in neonates.

About this research paper

What this paper is about

OBJECTIVE: To analysis the clinical characteristics of 1000 Hz probe tone tympanometry obtained from normal neonates who passed the OAE screening. To calculate the normal range of the variances of the tympanometry, which may serve as the guide for newborn hearing screening and detect middle ear function in neonates. METHODS: OAE screening were performed to screen the hearing with GSI-70 Automated OAE. The 1000 Hz probe tone tympanograms were obtained from 650 neonates who passed the TEOAE screening in both ears and were on the normal physiological conditions after birth with GSI Tympstar Version II Middle Ear Analyzer. The means, the standard deviation, the 95% confidence interval were analyzed. RESULTS: The 1000 Hz tympanometric data showed the 1Y1B1G tympanogram in 732 ears (56.3%), the 1Y3B1G tympanogram in 145 ears (11.2%), the 0Y0B0G tympanogram in 269 ears (20.7%), other shapes in 154 ears (11.8%) according to the Vanhuyse model. The 1000 Hz tympanometric datas showed the single-peaked tympanogram in 967 ears, the 95% confidence interval of the tympanometric data were as follows: tympanometric peak pressure (Tpp) was from -55.0 to 180.0 daPa, peak compensated static acoustic admittance (Peak Ytm) was 0.03-1.18 mmHo, tympanometric width (TW) was 70.0-230.0 daPa. CONCLUSIONS: The majority of 1000 Hz tympanograms from this study show the single-peaked in normal neonates. The 95% confidence interval of the tympanometric data may serve as a guide for hearing screening and detecting middle ear function in neonates.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To analysis the clinical characteristics of 1000 Hz probe tone tympanometry obtained from normal neonates who passed the OAE screening. To calculate the normal range of the variances of the tympanometry, which may serve as the guide for newborn hearing screening and detect middle ear function in neonates. METHODS: OAE screening were performed to screen the hearing with GSI-70 Automated OAE. The 1000 Hz probe tone tympanograms were obtained from 650 neonates who passed the TEOAE screening in both ears and were on the normal physiological conditions after birth with GSI Tympstar Version II Middle Ear Analyzer. The means, the standard deviation, the 95% confidence interval were analyzed. RESULTS: The 1000 Hz tympanometric data showed the 1Y1B1G tympanogram in 732 ears (56.3%), the 1Y3B1G tympanogram in 145 ears (11.2%), the 0Y0B0G tympanogram in 269 ears (20.7%), other shapes in 154 ears (11.8%) according to the Vanhuyse model. The 1000 Hz tympanometric datas showed the single-peaked tympanogram in 967 ears, the 95% confidence interval of the tympanometric data were as follows: tympanometric peak pressure (Tpp) was from -55.0 to 180.0 daPa, peak compensated static acoustic admittance (Peak Ytm) was 0.03-1.18 mmHo, tympanometric width (TW) was 70.0-230.0 daPa. CONCLUSIONS: The majority of 1000 Hz tympanograms from this study show the single-peaked in normal neonates. The 95% confidence interval of the tympanometric data may serve as a guide for hearing screening and detecting middle ear function in neonates.

Key concepts: Tympanometry, Medicine, Audiology, Confidence interval, Middle ear, Hearing loss, Audiometry, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
[Analysis of the 1000 Hz tympanometry in normal hearing neonates]. — Research Paper | ScholarLens