1992PubMedRequires access

[Evaluation of the phenylalanine tolerance test in detection of heterozygote carriers of phenylketonuria gene].

K Bernat

Open publisher page 0 citations

Abstract

The study aimed at identifying heterozygotic phenylketonuria gene carriers with phenylalanine tolerance test performed in Lublin region. Serum phenylalanine concentration has been assayed during fasting and 1 and 2 hours following oral phenylalanine load in the dose of 0.1 g per 1 kg body weight. The study involved 203 individuals of the general population and 29 heterozygotes with phenylketonuria gene. Blood serum phenylalanine was assayed with Guthrie' technique. Statistical analysis has shown that hyperphenylalaninemia is relatively frequent in fasting individuals of the general population (59.1%). The same was demonstrated in 5 heterozygotes. Phenylalanine tolerance test did not allow to identify heterozygotic carries of phenylketonuria gene in the general population though fasting and after phenylalanine load increased blood serum levels of this amino acid are a criterium of hyperphenylalaninemia in the group of tested individuals (29%).

About this research paper

What this paper is about

The study aimed at identifying heterozygotic phenylketonuria gene carriers with phenylalanine tolerance test performed in Lublin region. Serum phenylalanine concentration has been assayed during fasting and 1 and 2 hours following oral phenylalanine load in the dose of 0.1 g per 1 kg body weight. The study involved 203 individuals of the general population and 29 heterozygotes with phenylketonuria gene. Blood serum phenylalanine was assayed with Guthrie' technique. Statistical analysis has shown that hyperphenylalaninemia is relatively frequent in fasting individuals of the general population (59.1%). The same was demonstrated in 5 heterozygotes. Phenylalanine tolerance test did not allow to identify heterozygotic carries of phenylketonuria gene in the general population though fasting and after phenylalanine load increased blood serum levels of this amino acid are a criterium of hyperphenylalaninemia in the group of tested individuals (29%).

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The study aimed at identifying heterozygotic phenylketonuria gene carriers with phenylalanine tolerance test performed in Lublin region. Serum phenylalanine concentration has been assayed during fasting and 1 and 2 hours following oral phenylalanine load in the dose of 0.1 g per 1 kg body weight. The study involved 203 individuals of the general population and 29 heterozygotes with phenylketonuria gene. Blood serum phenylalanine was assayed with Guthrie' technique. Statistical analysis has shown that hyperphenylalaninemia is relatively frequent in fasting individuals of the general population (59.1%). The same was demonstrated in 5 heterozygotes. Phenylalanine tolerance test did not allow to identify heterozygotic carries of phenylketonuria gene in the general population though fasting and after phenylalanine load increased blood serum levels of this amino acid are a criterium of hyperphenylalaninemia in the group of tested individuals (29%).

Key concepts: Hyperphenylalaninemia, Phenylalanine, Heterozygote advantage, Phenylalanine hydroxylase, Medicine, Phenylketonurias, Population, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
[Evaluation of the phenylalanine tolerance test in detection of heterozygote carriers of phenylketonuria gene]. — Research Paper | ScholarLens