2007•Clinical Orthopaedics and Related ResearchRequires access

High-flexion TKA Designs

Adrija Sharma, Richard D. Komistek, Giles R. Scuderi, Harold Earl Cates

Open publisher page 54 citations

Abstract

To accommodate for high flexion, new total knee arthroplasties (TKAs) have been designed. Unlike older designs which have been found to exhibit decreasing contact area with increasing flexion, we hypothesized the new designs would be associated with improved contact mechanics. We compared in vivo contact mechanics for 10 subjects having a fixed-bearing high-flexion posterior-stabilized (LPS-Flex) TKA and 10 subjects having a fixed-bearing high-flexion posterior cruciate-retaining (CR-Flex) TKA. All subjects performed deep knee bends to maximum flexion while under fluoroscopic surveillance. In vivo kinematics obtained using a three-dimensional to two-dimensional registration technique, were input into a three-dimensional inverse dynamic mathematical model to determine the contact forces. The contact areas and contact stresses were determined using a deformable contact model. The contact forces, contact areas, and contact stresses in both these implants increased with increasing flexion. The medial contact area in the LPS-Flex was higher than the CR-Flex for most of the flexion cycle. The lateral contact area was higher in the CR-Flex than the LPS-Flex in early and midflexion ranges. Although the lateral contact stresses were similar in both implants, the CR-Flex experienced higher medial contact stress than the LPS-Flex throughout flexion. However, both these implants were able to maintain sufficient contact area so the contact stress values were well below the yield strength of crosslinked polyethylene.

About this research paper

What this paper is about

To accommodate for high flexion, new total knee arthroplasties (TKAs) have been designed. Unlike older designs which have been found to exhibit decreasing contact area with increasing flexion, we hypothesized the new designs would be associated with improved contact mechanics. We compared in vivo contact mechanics for 10 subjects having a fixed-bearing high-flexion posterior-stabilized (LPS-Flex) TKA and 10 subjects having a fixed-bearing high-flexion posterior cruciate-retaining (CR-Flex) TKA. All subjects performed deep knee bends to maximum flexion while under fluoroscopic surveillance. In vivo kinematics obtained using a three-dimensional to two-dimensional registration technique, were input into a three-dimensional inverse dynamic mathematical model to determine the contact forces. The contact areas and contact stresses were determined using a deformable contact model. The contact forces, contact areas, and contact stresses in both these implants increased with increasing flexion. The medial contact area in the LPS-Flex was higher than the CR-Flex for most of the flexion cycle. The lateral contact area was higher in the CR-Flex than the LPS-Flex in early and midflexion ranges. Although the lateral contact stresses were similar in both implants, the CR-Flex experienced higher medial contact stress than the LPS-Flex throughout flexion. However, both these implants were able to maintain sufficient contact area so the contact stress values were well below the yield strength of crosslinked polyethylene.

Why it matters

OpenAlex reports 54 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To accommodate for high flexion, new total knee arthroplasties (TKAs) have been designed. Unlike older designs which have been found to exhibit decreasing contact area with increasing flexion, we hypothesized the new designs would be associated with improved contact mechanics. We compared in vivo contact mechanics for 10 subjects having a fixed-bearing high-flexion posterior-stabilized (LPS-Flex) TKA and 10 subjects having a fixed-bearing high-flexion posterior cruciate-retaining (CR-Flex) TKA. All subjects performed deep knee bends to maximum flexion while under fluoroscopic surveillance. In vivo kinematics obtained using a three-dimensional to two-dimensional registration technique, were input into a three-dimensional inverse dynamic mathematical model to determine the contact forces. The contact areas and contact stresses were determined using a deformable contact model. The contact forces, contact areas, and contact stresses in both these implants increased with increasing flexion. The medial contact area in the LPS-Flex was higher than the CR-Flex for most of the flexion cycle. The lateral contact area was higher in the CR-Flex than the LPS-Flex in early and midflexion ranges. Although the lateral contact stresses were similar in both implants, the CR-Flex experienced higher medial contact stress than the LPS-Flex throughout flexion. However, both these implants were able to maintain sufficient contact area so the contact stress values were well below the yield strength of crosslinked polyethylene.

Key concepts: Contact mechanics, Contact area, Medicine, FLEX, Biomechanics, Orthodontics, Contact force, Knee flexion

Related papers

Back to paper searchBrowse research topicsOriginal source
High-flexion TKA Designs — Research Paper | ScholarLens