2010PubMedRequires access

[Quick determination of 39 hormones residues in infant formula by liquid chromatography-tandem mass spectrometry].

Weixia Zhu, Yafeng Liu, Ping Yuan, Jizhou Yang

Open publisher page 4 citations

Abstract

A quick confirmative method was developed for determining the residues of 17 glucocorticoids, 11 progesterones, 3 androgens and 8 estrogens in infant formula by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). The sample was extracted with acetonitrile at first. Then the lipid substances were removed by centrifugation under freezing condition and liquid-liquid extraction with hexane of the extract. The purification was carried out on hydrophilic-lipophilic solid-phase extraction columns and methanol was used as the eluted solvent. The detection of 39 analytes was carried out in the positive or negative multi-reaction monitoring (MRM) mode, separately. Acetonitrile-0.1% formic acid was used as the mobile phase and an ordinary silica gel C18 column was selected to separate the analytes in the positive mode. Acetonitrile-0.1% aqueous ammonia as mobile phase and the separation was carried out on an ultra-performance C18 column with a wide pH range in the negative mode. The limits of quantification (LOQ, S/N > or = 10) were 0.02-5 microg/kg. The overall recoveries varied from 59.5% to 117.9%, and the relative standard deviations (RSD) were between 6.4% and 16.3%. The real sample tests showed that the simple and accurate method can be used for determining the residues of multi-endogenous and chemically synthesized hormones in milk powders.

About this research paper

What this paper is about

A quick confirmative method was developed for determining the residues of 17 glucocorticoids, 11 progesterones, 3 androgens and 8 estrogens in infant formula by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). The sample was extracted with acetonitrile at first. Then the lipid substances were removed by centrifugation under freezing condition and liquid-liquid extraction with hexane of the extract. The purification was carried out on hydrophilic-lipophilic solid-phase extraction columns and methanol was used as the eluted solvent. The detection of 39 analytes was carried out in the positive or negative multi-reaction monitoring (MRM) mode, separately. Acetonitrile-0.1% formic acid was used as the mobile phase and an ordinary silica gel C18 column was selected to separate the analytes in the positive mode. Acetonitrile-0.1% aqueous ammonia as mobile phase and the separation was carried out on an ultra-performance C18 column with a wide pH range in the negative mode. The limits of quantification (LOQ, S/N > or = 10) were 0.02-5 microg/kg. The overall recoveries varied from 59.5% to 117.9%, and the relative standard deviations (RSD) were between 6.4% and 16.3%. The real sample tests showed that the simple and accurate method can be used for determining the residues of multi-endogenous and chemically synthesized hormones in milk powders.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A quick confirmative method was developed for determining the residues of 17 glucocorticoids, 11 progesterones, 3 androgens and 8 estrogens in infant formula by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). The sample was extracted with acetonitrile at first. Then the lipid substances were removed by centrifugation under freezing condition and liquid-liquid extraction with hexane of the extract. The purification was carried out on hydrophilic-lipophilic solid-phase extraction columns and methanol was used as the eluted solvent. The detection of 39 analytes was carried out in the positive or negative multi-reaction monitoring (MRM) mode, separately. Acetonitrile-0.1% formic acid was used as the mobile phase and an ordinary silica gel C18 column was selected to separate the analytes in the positive mode. Acetonitrile-0.1% aqueous ammonia as mobile phase and the separation was carried out on an ultra-performance C18 column with a wide pH range in the negative mode. The limits of quantification (LOQ, S/N > or = 10) were 0.02-5 microg/kg. The overall recoveries varied from 59.5% to 117.9%, and the relative standard deviations (RSD) were between 6.4% and 16.3%. The real sample tests showed that the simple and accurate method can be used for determining the residues of multi-endogenous and chemically synthesized hormones in milk powders.

Key concepts: Chemistry, Chromatography, Formic acid, Selected reaction monitoring, Acetonitrile, Extraction (chemistry), Analyte, Liquid chromatography–mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
[Quick determination of 39 hormones residues in infant formula by liquid chromatography-tandem mass spectrometry]. — Research Paper | ScholarLens