The Design of an Energy Efficient Highly Glazed Office Building
Åke Blomsterberg
Abstract
Åke Blomsterberg
Abstract
Many modern office buildings have highly glazed facades. Their energy efficiency and indoor climate is, however, being questioned. Therefore, when a modern office building (new construction) with larger glazing areas was planned, an investigation was carried out to determine the possibilities to: - efficiently use the increased access to daylight and thereby reduce the use of electricity for lighting and at the same time improve the visual comfort - ensure good thermal comfort - arrive at a reasonable total energy use, which is at the same level or preferably lower level than a traditional office building. The work was done by a project group that supported the design team with advanced energy, indoor climate and daylight simulations. Detailed performance specifications on energy use and indoor climate were worked out. The results show that the aims can be fulfilled if the following main requirements are fulfilled: - The glazing area should not exceed 45 % of the façade area. - The total solar transmittance of the glazing combined with solar shading must be lower than 0.1. - The U-value of the windows must be lower than 1.1 W/m²K. A double skin façade was chosen. An important conclusion is that coordination and cooperation throughout the building process is absolutely necessary. The building will be finished in 2007.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Many modern office buildings have highly glazed facades. Their energy efficiency and indoor climate is, however, being questioned. Therefore, when a modern office building (new construction) with larger glazing areas was planned, an investigation was carried out to determine the possibilities to: - efficiently use the increased access to daylight and thereby reduce the use of electricity for lighting and at the same time improve the visual comfort - ensure good thermal comfort - arrive at a reasonable total energy use, which is at the same level or preferably lower level than a traditional office building. The work was done by a project group that supported the design team with advanced energy, indoor climate and daylight simulations. Detailed performance specifications on energy use and indoor climate were worked out. The results show that the aims can be fulfilled if the following main requirements are fulfilled: - The glazing area should not exceed 45 % of the façade area. - The total solar transmittance of the glazing combined with solar shading must be lower than 0.1. - The U-value of the windows must be lower than 1.1 W/m²K. A double skin façade was chosen. An important conclusion is that coordination and cooperation throughout the building process is absolutely necessary. The building will be finished in 2007.
Key concepts: Daylight, Glazing, Facade, Architectural engineering, Daylighting, Work (physics), Curtain wall, Efficient energy use