2006•Lund University Publications (Lund University)Requires access

The Design of an Energy Efficient Highly Glazed Office Building

Åke Blomsterberg

Open publisher page 0 citations

Abstract

Many modern office buildings have highly glazed facades. Their energy efficiency and indoor climate is, however, being questioned. Therefore, when a modern office building (new construction) with larger glazing areas was planned, an investigation was carried out to determine the possibilities to: - efficiently use the increased access to daylight and thereby reduce the use of electricity for lighting and at the same time improve the visual comfort - ensure good thermal comfort - arrive at a reasonable total energy use, which is at the same level or preferably lower level than a traditional office building. The work was done by a project group that supported the design team with advanced energy, indoor climate and daylight simulations. Detailed performance specifications on energy use and indoor climate were worked out. The results show that the aims can be fulfilled if the following main requirements are fulfilled: - The glazing area should not exceed 45 % of the façade area. - The total solar transmittance of the glazing combined with solar shading must be lower than 0.1. - The U-value of the windows must be lower than 1.1 W/m²K. A double skin façade was chosen. An important conclusion is that coordination and cooperation throughout the building process is absolutely necessary. The building will be finished in 2007.

About this research paper

What this paper is about

Many modern office buildings have highly glazed facades. Their energy efficiency and indoor climate is, however, being questioned. Therefore, when a modern office building (new construction) with larger glazing areas was planned, an investigation was carried out to determine the possibilities to: - efficiently use the increased access to daylight and thereby reduce the use of electricity for lighting and at the same time improve the visual comfort - ensure good thermal comfort - arrive at a reasonable total energy use, which is at the same level or preferably lower level than a traditional office building. The work was done by a project group that supported the design team with advanced energy, indoor climate and daylight simulations. Detailed performance specifications on energy use and indoor climate were worked out. The results show that the aims can be fulfilled if the following main requirements are fulfilled: - The glazing area should not exceed 45 % of the façade area. - The total solar transmittance of the glazing combined with solar shading must be lower than 0.1. - The U-value of the windows must be lower than 1.1 W/m²K. A double skin façade was chosen. An important conclusion is that coordination and cooperation throughout the building process is absolutely necessary. The building will be finished in 2007.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Many modern office buildings have highly glazed facades. Their energy efficiency and indoor climate is, however, being questioned. Therefore, when a modern office building (new construction) with larger glazing areas was planned, an investigation was carried out to determine the possibilities to: - efficiently use the increased access to daylight and thereby reduce the use of electricity for lighting and at the same time improve the visual comfort - ensure good thermal comfort - arrive at a reasonable total energy use, which is at the same level or preferably lower level than a traditional office building. The work was done by a project group that supported the design team with advanced energy, indoor climate and daylight simulations. Detailed performance specifications on energy use and indoor climate were worked out. The results show that the aims can be fulfilled if the following main requirements are fulfilled: - The glazing area should not exceed 45 % of the façade area. - The total solar transmittance of the glazing combined with solar shading must be lower than 0.1. - The U-value of the windows must be lower than 1.1 W/m²K. A double skin façade was chosen. An important conclusion is that coordination and cooperation throughout the building process is absolutely necessary. The building will be finished in 2007.

Key concepts: Daylight, Glazing, Facade, Architectural engineering, Daylighting, Work (physics), Curtain wall, Efficient energy use

Related papers

Back to paper searchBrowse research topicsOriginal source
The Design of an Energy Efficient Highly Glazed Office Building — Research Paper | ScholarLens