2003•PubMedRequires access

Patient-derived fibrin sealant: clinical, preclinical, and biophysical aspects.

Henrik Kåre Kjaergård

Open publisher page 9 citations

Abstract

Today, there is an enormous interest in surgical sealant, not only for hemostasis, but also for binding of tissues together during surgery, and to improve wound healing. Man has imitated nature in developing fibrin sealant that is biodegradable. However, the risk of transmission of both known and unknown infectious agents can generally not be ruled out completely for plasma products from donors. In addition there is a considerable immunologic risk of using biological products of animal origin. Preclinical and clinical data has demonstrated that a safe and useable surgical fibrin sealant can be prepared from the patient's own blood using the enzyme batroxobin. Experimental data showed that patient-derived fibrin sealant provided enhanced instant adhesion strength and elasticity compared with conventional fibrin sealant due to its faster polymerisation rate. Test methods for fibrin sealant were found to be inaccurate, and we constructed and validated a new computer assisted test method to get information about elasticity and other dynamic properties of biological sealant. The method is highly reproducible and is the first validated using vital human tissue as the adhesion substrate. It takes about one half hour to prepared patient-derived fibrin sealant, which may turn a good operation into a perfect operation without any known risk.

About this research paper

What this paper is about

Today, there is an enormous interest in surgical sealant, not only for hemostasis, but also for binding of tissues together during surgery, and to improve wound healing. Man has imitated nature in developing fibrin sealant that is biodegradable. However, the risk of transmission of both known and unknown infectious agents can generally not be ruled out completely for plasma products from donors. In addition there is a considerable immunologic risk of using biological products of animal origin. Preclinical and clinical data has demonstrated that a safe and useable surgical fibrin sealant can be prepared from the patient's own blood using the enzyme batroxobin. Experimental data showed that patient-derived fibrin sealant provided enhanced instant adhesion strength and elasticity compared with conventional fibrin sealant due to its faster polymerisation rate. Test methods for fibrin sealant were found to be inaccurate, and we constructed and validated a new computer assisted test method to get information about elasticity and other dynamic properties of biological sealant. The method is highly reproducible and is the first validated using vital human tissue as the adhesion substrate. It takes about one half hour to prepared patient-derived fibrin sealant, which may turn a good operation into a perfect operation without any known risk.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Today, there is an enormous interest in surgical sealant, not only for hemostasis, but also for binding of tissues together during surgery, and to improve wound healing. Man has imitated nature in developing fibrin sealant that is biodegradable. However, the risk of transmission of both known and unknown infectious agents can generally not be ruled out completely for plasma products from donors. In addition there is a considerable immunologic risk of using biological products of animal origin. Preclinical and clinical data has demonstrated that a safe and useable surgical fibrin sealant can be prepared from the patient's own blood using the enzyme batroxobin. Experimental data showed that patient-derived fibrin sealant provided enhanced instant adhesion strength and elasticity compared with conventional fibrin sealant due to its faster polymerisation rate. Test methods for fibrin sealant were found to be inaccurate, and we constructed and validated a new computer assisted test method to get information about elasticity and other dynamic properties of biological sealant. The method is highly reproducible and is the first validated using vital human tissue as the adhesion substrate. It takes about one half hour to prepared patient-derived fibrin sealant, which may turn a good operation into a perfect operation without any known risk.

Key concepts: Sealant, Fibrin, Medicine, Fibrin Tissue Adhesive, Fibrinogen, Surgery, Hemostasis, Wound healing

Related papers

Back to paper searchBrowse research topicsOriginal source
Patient-derived fibrin sealant: clinical, preclinical, and biophysical aspects. — Research Paper | ScholarLens