1998•PubMedRequires access

Stress technetium-99m tetrofosmin myocardial scintigraphy: a new one-hour protocol for the detection of coronary artery disease.

J Matsuda, N Miyamoto, I Ikushima, Makoto Takenaga, Yasushi Koiwaya, Tanenao Eto

Open publisher page 1 citations

Abstract

A one-hour protocol for stress myocardial scintigraphy using technetium-99m (99mTc) tetrofosmin was compared with scintigraphy using thallium-201 (201Tl) for the detection of coronary artery disease in 43 consecutive patients who underwent stress 201Tl and 99mTc-tetrofosmin myocardial scintigraphy, and coronary arteriography within 1 week. For the stress 99mTc-tetrofosmin test, rest imaging data were acquired 20 min after intravenous injection of 5-7 mCi 99mTc-tetrofosmin, using a 3-head gamma camera collecting 20-sec views over 360 degrees. After dobutamine infusion or bicycle ergometer exercise, 20-25 mCi of 99mTc-tetrofosmin was additionally injected at peak stress. The stress images were acquired 15 min after the second injection with 5-sec views over 360 degrees. All patients also underwent 201Tl exercise and redistribution (4-hour) imaging following a standard protocol. The overall sensitivity for detecting coronary artery disease was 96.0%, with an overall specificity of 93.3% for both types of scintigraphy. Qualitative analyses of 21 conventionally divided left ventricular segments showed that the overall segmental concordance between the 99mTc-tetrofosmin and 201Tl imagings was 85.2% on the rest images and 82.1% on the stress images. The segmental concordance of the rest images was 87.0% in patients with neither significant stenosis nor myocardial infarction, 86.2% in patients with significant stenosis without myocardial infarction, and 82.9% in patients with significant stenosis and myocardial infarction, and the concordance values of the stress images were 85.4%, 87.5% and 75.6%, respectively. These preliminary results suggest that stress myocardial scintigraphy using the present new protocol is a promising approach for the detection of coronary artery disease, with diagnostic sensitivity and specificity comparable to those of stress 201Tl scintigraphy.

About this research paper

What this paper is about

A one-hour protocol for stress myocardial scintigraphy using technetium-99m (99mTc) tetrofosmin was compared with scintigraphy using thallium-201 (201Tl) for the detection of coronary artery disease in 43 consecutive patients who underwent stress 201Tl and 99mTc-tetrofosmin myocardial scintigraphy, and coronary arteriography within 1 week. For the stress 99mTc-tetrofosmin test, rest imaging data were acquired 20 min after intravenous injection of 5-7 mCi 99mTc-tetrofosmin, using a 3-head gamma camera collecting 20-sec views over 360 degrees. After dobutamine infusion or bicycle ergometer exercise, 20-25 mCi of 99mTc-tetrofosmin was additionally injected at peak stress. The stress images were acquired 15 min after the second injection with 5-sec views over 360 degrees. All patients also underwent 201Tl exercise and redistribution (4-hour) imaging following a standard protocol. The overall sensitivity for detecting coronary artery disease was 96.0%, with an overall specificity of 93.3% for both types of scintigraphy. Qualitative analyses of 21 conventionally divided left ventricular segments showed that the overall segmental concordance between the 99mTc-tetrofosmin and 201Tl imagings was 85.2% on the rest images and 82.1% on the stress images. The segmental concordance of the rest images was 87.0% in patients with neither significant stenosis nor myocardial infarction, 86.2% in patients with significant stenosis without myocardial infarction, and 82.9% in patients with significant stenosis and myocardial infarction, and the concordance values of the stress images were 85.4%, 87.5% and 75.6%, respectively. These preliminary results suggest that stress myocardial scintigraphy using the present new protocol is a promising approach for the detection of coronary artery disease, with diagnostic sensitivity and specificity comparable to those of stress 201Tl scintigraphy.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A one-hour protocol for stress myocardial scintigraphy using technetium-99m (99mTc) tetrofosmin was compared with scintigraphy using thallium-201 (201Tl) for the detection of coronary artery disease in 43 consecutive patients who underwent stress 201Tl and 99mTc-tetrofosmin myocardial scintigraphy, and coronary arteriography within 1 week. For the stress 99mTc-tetrofosmin test, rest imaging data were acquired 20 min after intravenous injection of 5-7 mCi 99mTc-tetrofosmin, using a 3-head gamma camera collecting 20-sec views over 360 degrees. After dobutamine infusion or bicycle ergometer exercise, 20-25 mCi of 99mTc-tetrofosmin was additionally injected at peak stress. The stress images were acquired 15 min after the second injection with 5-sec views over 360 degrees. All patients also underwent 201Tl exercise and redistribution (4-hour) imaging following a standard protocol. The overall sensitivity for detecting coronary artery disease was 96.0%, with an overall specificity of 93.3% for both types of scintigraphy. Qualitative analyses of 21 conventionally divided left ventricular segments showed that the overall segmental concordance between the 99mTc-tetrofosmin and 201Tl imagings was 85.2% on the rest images and 82.1% on the stress images. The segmental concordance of the rest images was 87.0% in patients with neither significant stenosis nor myocardial infarction, 86.2% in patients with significant stenosis without myocardial infarction, and 82.9% in patients with significant stenosis and myocardial infarction, and the concordance values of the stress images were 85.4%, 87.5% and 75.6%, respectively. These preliminary results suggest that stress myocardial scintigraphy using the present new protocol is a promising approach for the detection of coronary artery disease, with diagnostic sensitivity and specificity comparable to those of stress 201Tl scintigraphy.

Key concepts: Medicine, Scintigraphy, Coronary artery disease, Myocardial infarction, Cardiology, Internal medicine, Dobutamine, Stenosis

Related papers

Back to paper searchBrowse research topicsOriginal source
Stress technetium-99m tetrofosmin myocardial scintigraphy: a new one-hour protocol for the detection of coronary artery disease. — Research Paper | ScholarLens