Hemodynamic response to fluid repletion in patients with septic shock: evidence for early depression of cardiac performance.
Eric C. Rackow, Bella Kaufman, J. Falk, Mark E. Astiz, Max Harry Weil
Abstract
Eric C. Rackow, Bella Kaufman, J. Falk, Mark E. Astiz, Max Harry Weil
Abstract
We prospectively studied 18 patients with septic shock prior to and during volume infusion in order to evaluate their hemodynamic response to fluid repletion. Fluid challenge increased left heart filling pressure from 7.7 +/- 0.5 to 15.4 +/- 0.6 mm Hg (P less than .01). The increases in left ventricular filling were associated with significant increases in stroke volume index from 25.4 +/- 2.5 to 35.7 +/- 2.5 ml/min/M2 and cardiac index from 2.49 +/- 0.19 to 3.32 +/- 0.16 L/min/M2. However, at the end of fluid challenge, the patients exhibited depressed left ventricular performance as evidenced by a left ventricular stroke work index of 29.5 +/- 2.6 g X m/M2. Over the next 24 hours of maintenance fluid infusion, the left ventricular stroke work index increased to 36.8 +/- 4.2 g X m/M2 (not significant). These data suggest that volume infusion restores ventricular filling in patients with sepsis. Although fluid repletion increases stroke and cardiac output, depressed left ventricular performance appears to be an early finding in septic shock.
OpenAlex reports 81 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We prospectively studied 18 patients with septic shock prior to and during volume infusion in order to evaluate their hemodynamic response to fluid repletion. Fluid challenge increased left heart filling pressure from 7.7 +/- 0.5 to 15.4 +/- 0.6 mm Hg (P less than .01). The increases in left ventricular filling were associated with significant increases in stroke volume index from 25.4 +/- 2.5 to 35.7 +/- 2.5 ml/min/M2 and cardiac index from 2.49 +/- 0.19 to 3.32 +/- 0.16 L/min/M2. However, at the end of fluid challenge, the patients exhibited depressed left ventricular performance as evidenced by a left ventricular stroke work index of 29.5 +/- 2.6 g X m/M2. Over the next 24 hours of maintenance fluid infusion, the left ventricular stroke work index increased to 36.8 +/- 4.2 g X m/M2 (not significant). These data suggest that volume infusion restores ventricular filling in patients with sepsis. Although fluid repletion increases stroke and cardiac output, depressed left ventricular performance appears to be an early finding in septic shock.
Key concepts: Cardiac index, Stroke volume, Cardiac output, Septic shock, Medicine, Hemodynamics, Shock (circulatory), Cardiology