[Clinical usefulness of serum assay of EIA-CYFRA 21-1 in lung cancer].
Hiroaki Satoh, Hisanaga Yagyu, Masahiro Sumi, Hiromichi Ishikawa, Masashi Hamada, Takuya Suyama, Takeshi Naitoh, Masakí Inoue, Takefumí Saítoh, Yuki Uchida
Abstract
Hiroaki Satoh, Hisanaga Yagyu, Masahiro Sumi, Hiromichi Ishikawa, Masashi Hamada, Takuya Suyama, Takeshi Naitoh, Masakí Inoue, Takefumí Saítoh, Yuki Uchida
Abstract
Enzyme immunoassay CYFRA 21-1, a novel lung tumor marker presented in serum (upper limit of normal values: 3.5 ng/ml) was measured in 84 patients with lung cancer and 141 patients with benign respiratory diseases. The positive rate for CYFRA 21-1 in primary lung cancer was 70.3% and the false positive rate in respiratory diseases was 24.1%. In respect to the histological types of lung cancer, CYFRA 21-1 was elevated in 85.0% of squamous cell carcinoma and in 64.8% of other cell types of primary lung cancer. Elevated CYFRA 21-1 levels were found in 40% of Stage I-II, in 80.0% of Stage IIIA-B, and in 73.5% of Stage IV. The overall diagnostic efficiency was 53.4% for CYFRA 21-1 and 44.5% for CEA, respectively. Receiver operating characteristic (ROC) curve analysis suggested that CYFRA 21-1 test has an advantage over CEA. From the results of this study, CYFRA 21-1 was more efficient than CEA as primary diagnostic marker in lung cancer.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Enzyme immunoassay CYFRA 21-1, a novel lung tumor marker presented in serum (upper limit of normal values: 3.5 ng/ml) was measured in 84 patients with lung cancer and 141 patients with benign respiratory diseases. The positive rate for CYFRA 21-1 in primary lung cancer was 70.3% and the false positive rate in respiratory diseases was 24.1%. In respect to the histological types of lung cancer, CYFRA 21-1 was elevated in 85.0% of squamous cell carcinoma and in 64.8% of other cell types of primary lung cancer. Elevated CYFRA 21-1 levels were found in 40% of Stage I-II, in 80.0% of Stage IIIA-B, and in 73.5% of Stage IV. The overall diagnostic efficiency was 53.4% for CYFRA 21-1 and 44.5% for CEA, respectively. Receiver operating characteristic (ROC) curve analysis suggested that CYFRA 21-1 test has an advantage over CEA. From the results of this study, CYFRA 21-1 was more efficient than CEA as primary diagnostic marker in lung cancer.
Key concepts: Lung cancer, Medicine, Internal medicine, Stage (stratigraphy), Receiver operating characteristic, Immunoassay, Cancer, Gastroenterology