Diagnostic Role of Tc-99m MIBI Scintimammography in Suspected Breast Cancer Patients: Results of Unicenter Trial
Seong‐Jang Kim, In‐Ju Kim, Yong-Ki Kim, Youngtae Bae
Abstract
Seong‐Jang Kim, In‐Ju Kim, Yong-Ki Kim, Youngtae Bae
Abstract
Purpose: Tc-99m MIBI scintimammography has been validated as an useful non-invasive diagnostic tool for the primary breast cancer. But most studies have included small population of patients. We have experienced a large study population and investigated the diagnostic usefulness of Tc-99m MIBI scintimammography in detection of primary breast cancer and axillary lymph node metastasis. Materials and Methods: This study included 305 patients who underwent scintimammogtaphy for palpable breast masses or abnormal radiologic findings. Tc-99m MIBI scintimammography was performed 10 minutes after intravenous injection of 925 MBq of Tc-99m MIBI. If the early image revealed abnormal finding, 3 hour delayed image was also acquired. We calculated early and delayed lesion to non-lesion ratios (L/N). The pathologic diagnosis was obtained from surgical operation or FNAB and compared with the results of Tc-99m MIBI scintimammography. Results: Malignant breast diseases were 155 and benign ones were 150. Tc-99m MIBI scintimammography revealed 132 true positive, 23 false negative, 10 false positive, and 140 true negative cases. The sensitivity, specificity, positive predictive value and negative predictive value for the primary breast cancer detection were 85.2%, 93.4%, 92.9%, and 85.9%, respectively. The sensitivity, specificity, positive predictive and negative predictive values of Tc-99m MIBI scintimammography in detecting metastatic axillary lymph node involvement were 22%, 90.4%, 61.9% and 62.3%, respectively. Early L/N of malignant breast disease was significantly higher than that of benign one (, p=0.01). Delayed L/N had no significant difference between malignant and benign breast diseases (, p=0.43). Conclusion: Our study revealed that Tc-99m MIBI scintimammography was an useful diagnostic tool for the diagnosis of breast cancer. And early L/N ratio might provide complementary role in the detection of breast cancer. But the Tc-99m MIBI scintimammography had limited value in the detection of small breast cancer (less than 1 cm) and axillary lymph node metastasis.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Purpose: Tc-99m MIBI scintimammography has been validated as an useful non-invasive diagnostic tool for the primary breast cancer. But most studies have included small population of patients. We have experienced a large study population and investigated the diagnostic usefulness of Tc-99m MIBI scintimammography in detection of primary breast cancer and axillary lymph node metastasis. Materials and Methods: This study included 305 patients who underwent scintimammogtaphy for palpable breast masses or abnormal radiologic findings. Tc-99m MIBI scintimammography was performed 10 minutes after intravenous injection of 925 MBq of Tc-99m MIBI. If the early image revealed abnormal finding, 3 hour delayed image was also acquired. We calculated early and delayed lesion to non-lesion ratios (L/N). The pathologic diagnosis was obtained from surgical operation or FNAB and compared with the results of Tc-99m MIBI scintimammography. Results: Malignant breast diseases were 155 and benign ones were 150. Tc-99m MIBI scintimammography revealed 132 true positive, 23 false negative, 10 false positive, and 140 true negative cases. The sensitivity, specificity, positive predictive value and negative predictive value for the primary breast cancer detection were 85.2%, 93.4%, 92.9%, and 85.9%, respectively. The sensitivity, specificity, positive predictive and negative predictive values of Tc-99m MIBI scintimammography in detecting metastatic axillary lymph node involvement were 22%, 90.4%, 61.9% and 62.3%, respectively. Early L/N of malignant breast disease was significantly higher than that of benign one (, p=0.01). Delayed L/N had no significant difference between malignant and benign breast diseases (, p=0.43). Conclusion: Our study revealed that Tc-99m MIBI scintimammography was an useful diagnostic tool for the diagnosis of breast cancer. And early L/N ratio might provide complementary role in the detection of breast cancer. But the Tc-99m MIBI scintimammography had limited value in the detection of small breast cancer (less than 1 cm) and axillary lymph node metastasis.
Key concepts: Scintimammography, Medicine, Breast cancer, Radiology, Lymph node, Nuclear medicine, Population, Technetium (99mTc) sestamibi