[Second generation hepatitis-C virus test and polymerase chain reaction in anti-C 100 negative patients with chronic non-A, non-B hepatitis].
G Zala, J Havelka, Wicki An, Joller-Jemelka Hi, Beat Meier, Matthias Schmid, H Bühler
Abstract
G Zala, J Havelka, Wicki An, Joller-Jemelka Hi, Beat Meier, Matthias Schmid, H Bühler
Abstract
The aim of our study was to evaluate whether a negative HCV test of the first generation (HCV-ELISA 1) using the antigen C100-3 excludes chronic HCV infection, or whether patients exist who are negative for antibodies to C100-3 in spite of chronic hepatitis C. 27 patients with histologically proven chronic non-A, non-B hepatitis, all of whom were HCV-ELISA 1 negative, were tested by the HCV test systems of the second generation (Ortho-HCV-ELISA 2 and Chiron-HCV-RIBA 2) based on the distinct HCV antigens 5-1-1, C100-3, C33c and C22-3. To determine the presence of viremia, serum samples were also tested for HCV-RNA with "nested" PCR. 10 of 27 patients proved to be persistently negative when tested with the second generation assays. One patient showed low grade reactivity by HCV-ELISA 2, but non-reactivity by HCV-RIBA 2. In none of these 11 patients was HCV-RNA detected. 16 (60%) of 27 patients negative with HCV-ELISA 1 were positive with HCV-ELISA 2. HCV-RIBA 2 detected antibodies to the structural core antigen C22-3 in all of these 16 patients and antibodies to the non-structural antigen C33c in 14 of them, while antibodies to 5-1-1 or C100-3 were not found in any of these cases. 10 (63%) of the 16 HCV-ELISA 1 negative, but HCV-ELISA 2 and HCV-RIBA 2 positive patients were positive for HCV-RNA by "nested" PCR.(ABSTRACT TRUNCATED AT 250 WORDS)
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The aim of our study was to evaluate whether a negative HCV test of the first generation (HCV-ELISA 1) using the antigen C100-3 excludes chronic HCV infection, or whether patients exist who are negative for antibodies to C100-3 in spite of chronic hepatitis C. 27 patients with histologically proven chronic non-A, non-B hepatitis, all of whom were HCV-ELISA 1 negative, were tested by the HCV test systems of the second generation (Ortho-HCV-ELISA 2 and Chiron-HCV-RIBA 2) based on the distinct HCV antigens 5-1-1, C100-3, C33c and C22-3. To determine the presence of viremia, serum samples were also tested for HCV-RNA with "nested" PCR. 10 of 27 patients proved to be persistently negative when tested with the second generation assays. One patient showed low grade reactivity by HCV-ELISA 2, but non-reactivity by HCV-RIBA 2. In none of these 11 patients was HCV-RNA detected. 16 (60%) of 27 patients negative with HCV-ELISA 1 were positive with HCV-ELISA 2. HCV-RIBA 2 detected antibodies to the structural core antigen C22-3 in all of these 16 patients and antibodies to the non-structural antigen C33c in 14 of them, while antibodies to 5-1-1 or C100-3 were not found in any of these cases. 10 (63%) of the 16 HCV-ELISA 1 negative, but HCV-ELISA 2 and HCV-RIBA 2 positive patients were positive for HCV-RNA by "nested" PCR.(ABSTRACT TRUNCATED AT 250 WORDS)
Key concepts: Medicine, Hepatitis C virus, Antibody, Virology, Antigen, Viremia, Flaviviridae, Hepatitis C