1982•American Journal of Physiology-Heart and Circulatory PhysiologyRequires access

Responses of aortic baroreceptors to changes of aortic blood flow and pressure in rat

John D. Charlton, Alex J. Baertschi

Open publisher page 17 citations

Abstract

To test the hypothesis that aortic baroreceptors may respond not only to changes of aortic pressure but also to changes of aortic flow, sinusoidal flow waves were applied at 1 Hz to the aorta of urethan-anesthetized rats by infusion and withdrawal of 90 microliters blood with a pump while aortic blood pressure and single baroreceptor fiber activity were monitored. Averages from 20 to 30 pressure wave forms and nerve impulse histograms were established by computer for each single fiber during control (no pump), pump instroke (I), and outstroke (O). Fiber activity increased 20 +/- 3% (mean +/- SEM, n = 28 fibers) and decreased 23 +/- 4% with respect to control during I and O, respectively, whereas estimated changes of aortic flow were +/- 21%. The number of nerve impulses increased (I) and decreased (O) mainly during late systolic pressure rise did not change significantly, but the rate of late systolic pressure fall decreased 42 +/- 7 mmHg/s (I) and increased 39 +/- 11 mmHg/s (O). These results suggest that, because of the rate sensitivity of aortic baroreceptors, changes in aortic flow are reflected in changes of nerve impulse firing patterns during the blood pressure decrease in late systole, even in the absence of significant changes in systolic, diastolic, and pulse pressure.

About this research paper

What this paper is about

To test the hypothesis that aortic baroreceptors may respond not only to changes of aortic pressure but also to changes of aortic flow, sinusoidal flow waves were applied at 1 Hz to the aorta of urethan-anesthetized rats by infusion and withdrawal of 90 microliters blood with a pump while aortic blood pressure and single baroreceptor fiber activity were monitored. Averages from 20 to 30 pressure wave forms and nerve impulse histograms were established by computer for each single fiber during control (no pump), pump instroke (I), and outstroke (O). Fiber activity increased 20 +/- 3% (mean +/- SEM, n = 28 fibers) and decreased 23 +/- 4% with respect to control during I and O, respectively, whereas estimated changes of aortic flow were +/- 21%. The number of nerve impulses increased (I) and decreased (O) mainly during late systolic pressure rise did not change significantly, but the rate of late systolic pressure fall decreased 42 +/- 7 mmHg/s (I) and increased 39 +/- 11 mmHg/s (O). These results suggest that, because of the rate sensitivity of aortic baroreceptors, changes in aortic flow are reflected in changes of nerve impulse firing patterns during the blood pressure decrease in late systole, even in the absence of significant changes in systolic, diastolic, and pulse pressure.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To test the hypothesis that aortic baroreceptors may respond not only to changes of aortic pressure but also to changes of aortic flow, sinusoidal flow waves were applied at 1 Hz to the aorta of urethan-anesthetized rats by infusion and withdrawal of 90 microliters blood with a pump while aortic blood pressure and single baroreceptor fiber activity were monitored. Averages from 20 to 30 pressure wave forms and nerve impulse histograms were established by computer for each single fiber during control (no pump), pump instroke (I), and outstroke (O). Fiber activity increased 20 +/- 3% (mean +/- SEM, n = 28 fibers) and decreased 23 +/- 4% with respect to control during I and O, respectively, whereas estimated changes of aortic flow were +/- 21%. The number of nerve impulses increased (I) and decreased (O) mainly during late systolic pressure rise did not change significantly, but the rate of late systolic pressure fall decreased 42 +/- 7 mmHg/s (I) and increased 39 +/- 11 mmHg/s (O). These results suggest that, because of the rate sensitivity of aortic baroreceptors, changes in aortic flow are reflected in changes of nerve impulse firing patterns during the blood pressure decrease in late systole, even in the absence of significant changes in systolic, diastolic, and pulse pressure.

Key concepts: Baroreceptor, Aortic pressure, Blood pressure, Aorta, Internal medicine, Cardiology, Pulse pressure, Blood flow

Related papers

Back to paper searchBrowse research topicsOriginal source
Responses of aortic baroreceptors to changes of aortic blood flow and pressure in rat — Research Paper | ScholarLens