40 determinations of the stroke volume were carried out by impedance cardiography in one and the same subject. The stroke volume varied between 136 and 209 ml (x, x = 169 ml, S.D. = 17.5 ml). The mean error was in the same range as obtained by the Fick principle or by dye-dilution technique as referred to the literature. However, analysing the factors affecting the variability of the determined stroke volumes we may infer, the Kubicek formula for stroke volume is neither theoretically nor empirically sufficiently proved. A quantitative determination of the stroke volume or of any other circulatory quantity by the impedance cardiography seems to be impossible by our present method of procedure.

About this research paper

What this paper is about

40 determinations of the stroke volume were carried out by impedance cardiography in one and the same subject. The stroke volume varied between 136 and 209 ml (x, x = 169 ml, S.D. = 17.5 ml). The mean error was in the same range as obtained by the Fick principle or by dye-dilution technique as referred to the literature. However, analysing the factors affecting the variability of the determined stroke volumes we may infer, the Kubicek formula for stroke volume is neither theoretically nor empirically sufficiently proved. A quantitative determination of the stroke volume or of any other circulatory quantity by the impedance cardiography seems to be impossible by our present method of procedure.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

40 determinations of the stroke volume were carried out by impedance cardiography in one and the same subject. The stroke volume varied between 136 and 209 ml (x, x = 169 ml, S.D. = 17.5 ml). The mean error was in the same range as obtained by the Fick principle or by dye-dilution technique as referred to the literature. However, analysing the factors affecting the variability of the determined stroke volumes we may infer, the Kubicek formula for stroke volume is neither theoretically nor empirically sufficiently proved. A quantitative determination of the stroke volume or of any other circulatory quantity by the impedance cardiography seems to be impossible by our present method of procedure.

Key concepts: Impedance cardiography, Stroke volume, Medicine, Reproducibility, Stroke (engine), Volume (thermodynamics), Cardiac output, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
[The reproducibility of stroke-volume measurements by impedance cardiography. A critical analysis (author's transl)]. — Research Paper | ScholarLens