1957OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)Requires access

A SCINTILLATION $gamma$ SPECTROMETER WITH AUTOMATIC RECORDING

D. Kiss, Lajos Matus, Z. Zâmori

Open publisher page 0 citations

Abstract

A single-crystal scintillation spectrometer was built for measuring gamma rays produced in (n, gamma ) reactions. The resolving power was found to be 9.5%: the non-linearity was less thin 1% up to 4.4 Mev. The stability of the arrangement was satisfactory. For the full automatic plotting of the whole spectrum. 5 minutes are needed. A modification of the spectrometer is suggested mixing possible a direct reading of the line intensity from the peak height and calculations are carried out for a given case. (auth)

About this research paper

What this paper is about

A single-crystal scintillation spectrometer was built for measuring gamma rays produced in (n, gamma ) reactions. The resolving power was found to be 9.5%: the non-linearity was less thin 1% up to 4.4 Mev. The stability of the arrangement was satisfactory. For the full automatic plotting of the whole spectrum. 5 minutes are needed. A modification of the spectrometer is suggested mixing possible a direct reading of the line intensity from the peak height and calculations are carried out for a given case. (auth)

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A single-crystal scintillation spectrometer was built for measuring gamma rays produced in (n, gamma ) reactions. The resolving power was found to be 9.5%: the non-linearity was less thin 1% up to 4.4 Mev. The stability of the arrangement was satisfactory. For the full automatic plotting of the whole spectrum. 5 minutes are needed. A modification of the spectrometer is suggested mixing possible a direct reading of the line intensity from the peak height and calculations are carried out for a given case. (auth)

Key concepts: Spectrometer, Scintillation, Scintillation counter, Optics, Physics, Mixing (physics), Linearity, Gamma ray

Related papers

Back to paper searchBrowse research topicsOriginal source
A SCINTILLATION $gamma$ SPECTROMETER WITH AUTOMATIC RECORDING — Research Paper | ScholarLens