2007PubMedRequires access

[Detection of alpha thalassemia using real-time PCR and dissociation curve analysis].

Mei Yan, Lirong Wang, Zhanyong Wang, Yan Zhou, Yan Liang, Bai Xiao, Jingzhong Liu

Open publisher page 5 citations

Abstract

OBJECTIVE: To establish an automatic, high throughput, quick detection method of alpha thalassemia. METHODS: The genotypes of -alpha(4.2) and -alpha(3.7) were detected by two real-time fluorescence PCRs using SYBR-Green1 (SYBR-PCR) with the analysis of dissociation curve (DC) and melting temperature (Tm). The PCR products were recombined into T-vector and the correct cloning was selected as positive control. Sensitivities were gained from a serious dilution of the recombinant as SYBR-PCR template, from which detection deadlines for two kinds of alleles could be determined. Totally 110 samples were detected by this technique. RESULTS: The length of product of -alpha(4.2) and -alpha(3.7) were 1.65 kb and 1.9 kb respectively, and the Tm were (81.5+/-0.5) degrees C and (82.5+/-0.5) degrees C respectively. The detection deadline were 9 x 10(2 ) copies and 4.3 x 10(2) copies respectively. The sensitivity of the technique was much higher than that of regular PCR plus gel electrophoresis method, and the detection results of the technique were the same as that of multiplex PCR. CONCLUSION: The genotypes of -alpha(4.2), -alpha(3.7), non-deletion alpha alpha/and --(SEA) can be sensitively, exactly diagnosed by the real-time PCR with SYBR-Green1 combined with the dissociation curve analysis. The assay is automatic, low-cost, high throughput, and easy for quality control without fluorescence probe.

About this research paper

What this paper is about

OBJECTIVE: To establish an automatic, high throughput, quick detection method of alpha thalassemia. METHODS: The genotypes of -alpha(4.2) and -alpha(3.7) were detected by two real-time fluorescence PCRs using SYBR-Green1 (SYBR-PCR) with the analysis of dissociation curve (DC) and melting temperature (Tm). The PCR products were recombined into T-vector and the correct cloning was selected as positive control. Sensitivities were gained from a serious dilution of the recombinant as SYBR-PCR template, from which detection deadlines for two kinds of alleles could be determined. Totally 110 samples were detected by this technique. RESULTS: The length of product of -alpha(4.2) and -alpha(3.7) were 1.65 kb and 1.9 kb respectively, and the Tm were (81.5+/-0.5) degrees C and (82.5+/-0.5) degrees C respectively. The detection deadline were 9 x 10(2 ) copies and 4.3 x 10(2) copies respectively. The sensitivity of the technique was much higher than that of regular PCR plus gel electrophoresis method, and the detection results of the technique were the same as that of multiplex PCR. CONCLUSION: The genotypes of -alpha(4.2), -alpha(3.7), non-deletion alpha alpha/and --(SEA) can be sensitively, exactly diagnosed by the real-time PCR with SYBR-Green1 combined with the dissociation curve analysis. The assay is automatic, low-cost, high throughput, and easy for quality control without fluorescence probe.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To establish an automatic, high throughput, quick detection method of alpha thalassemia. METHODS: The genotypes of -alpha(4.2) and -alpha(3.7) were detected by two real-time fluorescence PCRs using SYBR-Green1 (SYBR-PCR) with the analysis of dissociation curve (DC) and melting temperature (Tm). The PCR products were recombined into T-vector and the correct cloning was selected as positive control. Sensitivities were gained from a serious dilution of the recombinant as SYBR-PCR template, from which detection deadlines for two kinds of alleles could be determined. Totally 110 samples were detected by this technique. RESULTS: The length of product of -alpha(4.2) and -alpha(3.7) were 1.65 kb and 1.9 kb respectively, and the Tm were (81.5+/-0.5) degrees C and (82.5+/-0.5) degrees C respectively. The detection deadline were 9 x 10(2 ) copies and 4.3 x 10(2) copies respectively. The sensitivity of the technique was much higher than that of regular PCR plus gel electrophoresis method, and the detection results of the technique were the same as that of multiplex PCR. CONCLUSION: The genotypes of -alpha(4.2), -alpha(3.7), non-deletion alpha alpha/and --(SEA) can be sensitively, exactly diagnosed by the real-time PCR with SYBR-Green1 combined with the dissociation curve analysis. The assay is automatic, low-cost, high throughput, and easy for quality control without fluorescence probe.

Key concepts: Molecular biology, SYBR Green I, Melting curve analysis, Standard curve, Real-time polymerase chain reaction, Multiplex, Alpha-thalassemia, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
[Detection of alpha thalassemia using real-time PCR and dissociation curve analysis]. — Research Paper | ScholarLens