Determination of active ingredients in mutouhui by capillary electrophoresis with electrochemical detection.
Cheng-Huai Geng, Weiyu Wang, Miao Chu Lin, Jiannong Ye
Abstract
Cheng-Huai Geng, Weiyu Wang, Miao Chu Lin, Jiannong Ye
Abstract
Capillary zone electrophoresis with electrochemical detection has been used for the separation and determination of scopoletin, hyperin, chlorogenic acid, and quercetin in Mutouhui. The effects of several important factors, including running buffer acidity, separation voltage, and working potential, were evaluated to achieve the optimum conditions. The working electrode was a 300-microm carbon disk electrode at a working potential of + 0.95 V (versus saturated calomel electrode). Under the optimum conditions, the analytes can be well separated within 20 min in a 75-cm-long fused-silica capillary. The current response was linear over two orders of magnitude with detection limits (S/N = 3) ranging from 2.70 x 10(-8) g/mL to 1.30 x 10(-7) g/mL for all analytes. This method was used successfully in the analysis of Mutouhui, and the assay results were satisfactory.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Capillary zone electrophoresis with electrochemical detection has been used for the separation and determination of scopoletin, hyperin, chlorogenic acid, and quercetin in Mutouhui. The effects of several important factors, including running buffer acidity, separation voltage, and working potential, were evaluated to achieve the optimum conditions. The working electrode was a 300-microm carbon disk electrode at a working potential of + 0.95 V (versus saturated calomel electrode). Under the optimum conditions, the analytes can be well separated within 20 min in a 75-cm-long fused-silica capillary. The current response was linear over two orders of magnitude with detection limits (S/N = 3) ranging from 2.70 x 10(-8) g/mL to 1.30 x 10(-7) g/mL for all analytes. This method was used successfully in the analysis of Mutouhui, and the assay results were satisfactory.
Key concepts: Capillary electrophoresis, Saturated calomel electrode, Working electrode, Chemistry, Chromatography, Analyte, Chlorogenic acid, Detection limit