[Left ventricular function in congenital hypothyroidism neonates before and after thyroxine substitution therapy].
Shanshan Mao, Zhengyan Zhao, Guo-ping Jiang
Abstract
Shanshan Mao, Zhengyan Zhao, Guo-ping Jiang
Abstract
OBJECTIVE: To evaluate left the systolic and diastolic functions in neonates with congenital hypothyroidism (CH) as well as the effect of thyroxine substitution therapy on left ventricular function and its correlation with thyroid hormones serum levels. METHODS: M-mode echocardiography was used to examine the left ventricular ejection fraction (LVEF) and left ventricular fractional shortening (LVFS), pulse wave Doppler was used to examine the peak early diastolic mitral inflow velocity (E(m)) and peak late diastolic mitral inflow velocity (A(m)), quantitative tissue velocity imaging (QTVI) was used to examine the systolic peak mitral annular velocity (s(m)), early diastolic peak mitral annular velocity (E(m)), and the late diastolic peak mitral annular velocity (a(m)), and tissue tracking imaging (TTI) was used to detect the systolic mitral annular displacement (MAD) in 40 neonates with congenital hypothyroidism aged 15-28 days before and after 1-month levothyroxine substitution treatment. Thirty normal neonates were used as controls. Chemiluminescent immunoassay was used to measure the TT(3), TT(4) and TSH levels. Correlation analysis was also made between the ventricular function parameters and the serum TT(3), TT(4), and TSH levels. RESULTS: The left systolic function parameters (LVEF, s(m), MAD, E(m) and e(m)) was 0.61 +/- 0.08, 2.60 cm/s +/- 0.60 cm/s, 0.29 cm +/- 0.06 cm, 0.59 m/s +/- 0.12 m/s and 2.72 cm/s +/- 1.43 cm/s respectively, in CH group, and 0.67 +/- 0.06, 3.25 cm/s +/- 0.51 cm/s, 0.41 cm +/- 0.08 cm, 0.72 m/s +/- 0.11 m/s and 4.51 cm/s +/- 1.23 cm/s in control group (P < 0.01). Left function in CH neonates before treatment were all lower than those of the controls (P < 0.01), which significantly increase after 1-months L-T(4) substitution therapy, 0.69 +/- 0.05, 3.46 cm/s +/- 0.64 cm/s, 0.45 cm +/- 0.08 cm, 0.82 m/s +/- 0.17 m/s and 5.09 cm/s +/- 1.37 cm/s, (P < 0.01). Those parameters were positively correlated with TT(4) serum levels (P < 0.01), and were negatively correlated with TSH (all P < 0.01). In particular, MAD, sm, E(m), and em were highly correlated with serum TT(4) and TSH (r = 0.667, 0.538, 0.478, and 0.599 respectively, all P < 0.001;and r = -0.670, -0.521, -0.490, and -0.583 respectively, all P < 0.001). CONCLUSION: Neonates with CH have lower left systolic and diastolic functions. Early L-T(4) substitution therapy can reverse these changes.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To evaluate left the systolic and diastolic functions in neonates with congenital hypothyroidism (CH) as well as the effect of thyroxine substitution therapy on left ventricular function and its correlation with thyroid hormones serum levels. METHODS: M-mode echocardiography was used to examine the left ventricular ejection fraction (LVEF) and left ventricular fractional shortening (LVFS), pulse wave Doppler was used to examine the peak early diastolic mitral inflow velocity (E(m)) and peak late diastolic mitral inflow velocity (A(m)), quantitative tissue velocity imaging (QTVI) was used to examine the systolic peak mitral annular velocity (s(m)), early diastolic peak mitral annular velocity (E(m)), and the late diastolic peak mitral annular velocity (a(m)), and tissue tracking imaging (TTI) was used to detect the systolic mitral annular displacement (MAD) in 40 neonates with congenital hypothyroidism aged 15-28 days before and after 1-month levothyroxine substitution treatment. Thirty normal neonates were used as controls. Chemiluminescent immunoassay was used to measure the TT(3), TT(4) and TSH levels. Correlation analysis was also made between the ventricular function parameters and the serum TT(3), TT(4), and TSH levels. RESULTS: The left systolic function parameters (LVEF, s(m), MAD, E(m) and e(m)) was 0.61 +/- 0.08, 2.60 cm/s +/- 0.60 cm/s, 0.29 cm +/- 0.06 cm, 0.59 m/s +/- 0.12 m/s and 2.72 cm/s +/- 1.43 cm/s respectively, in CH group, and 0.67 +/- 0.06, 3.25 cm/s +/- 0.51 cm/s, 0.41 cm +/- 0.08 cm, 0.72 m/s +/- 0.11 m/s and 4.51 cm/s +/- 1.23 cm/s in control group (P < 0.01). Left function in CH neonates before treatment were all lower than those of the controls (P < 0.01), which significantly increase after 1-months L-T(4) substitution therapy, 0.69 +/- 0.05, 3.46 cm/s +/- 0.64 cm/s, 0.45 cm +/- 0.08 cm, 0.82 m/s +/- 0.17 m/s and 5.09 cm/s +/- 1.37 cm/s, (P < 0.01). Those parameters were positively correlated with TT(4) serum levels (P < 0.01), and were negatively correlated with TSH (all P < 0.01). In particular, MAD, sm, E(m), and em were highly correlated with serum TT(4) and TSH (r = 0.667, 0.538, 0.478, and 0.599 respectively, all P < 0.001;and r = -0.670, -0.521, -0.490, and -0.583 respectively, all P < 0.001). CONCLUSION: Neonates with CH have lower left systolic and diastolic functions. Early L-T(4) substitution therapy can reverse these changes.
Key concepts: Internal medicine, Ejection fraction, Medicine, Cardiology, Diastole, Diastolic function, Levothyroxine, Doppler imaging