Self‐tonometry as a complement in the investigation of glaucoma patients
Enping Chen, Laurence Quérat, Christina Åkerstedt
Abstract
Open-access reader
Enping Chen, Laurence Quérat, Christina Åkerstedt
Abstract
Open-access reader
PURPOSE: To evaluate the reliability of intraocular pressure measured by patients with glaucoma themselves using a new hand-held tonometer and to observe whether the intraocular pressure (IOP) variations have the same pattern on different days while glaucoma treatment is constant. METHODS: Eighty-seven patients diagnosed with open-angle glaucoma or ocular hypertension were recruited to the study. Intraocular pressure measured using Goldmann applanation tonometry (GAT) was compared with IOP measured using tonometry at baseline and on the second visit. Patients measured their IOP at home using the hand-held tonometers. RESULTS: measurements were within 3 mmHg of the GAT measurements. Approximately 64% of the study eyes had higher IOP in the morning than in the afternoon/evening. Circadian patterns differed between consecutive days in 47% of the study eyes. There were IOP peaks outside office hours in up to 16% of the study eyes. CONCLUSION: Measurements made using rebound self-tonometry are accurate and could be used to complement the investigation of patients with glaucoma. Intraocular pressure curves provide valuable data usable when adapting glaucoma treatment.
OpenAlex reports 41 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: To evaluate the reliability of intraocular pressure measured by patients with glaucoma themselves using a new hand-held tonometer and to observe whether the intraocular pressure (IOP) variations have the same pattern on different days while glaucoma treatment is constant. METHODS: Eighty-seven patients diagnosed with open-angle glaucoma or ocular hypertension were recruited to the study. Intraocular pressure measured using Goldmann applanation tonometry (GAT) was compared with IOP measured using tonometry at baseline and on the second visit. Patients measured their IOP at home using the hand-held tonometers. RESULTS: measurements were within 3 mmHg of the GAT measurements. Approximately 64% of the study eyes had higher IOP in the morning than in the afternoon/evening. Circadian patterns differed between consecutive days in 47% of the study eyes. There were IOP peaks outside office hours in up to 16% of the study eyes. CONCLUSION: Measurements made using rebound self-tonometry are accurate and could be used to complement the investigation of patients with glaucoma. Intraocular pressure curves provide valuable data usable when adapting glaucoma treatment.
Key concepts: Intraocular pressure, Medicine, Glaucoma, Ophthalmology, Morning, Evening, Ocular hypertension, Internal medicine