Cardiac repolarization is prolonged in diabetes mellitus (DM), however the distribution of repolarization durations in diabetic hearts is unknown. We estimated the ventricular repolarization pattern and its relation to the ECG phenomena in diabetic mice. Potential mapping was performed on the anterior ventricular surface in healthy (n=18) and alloxan-induced diabetic (n=12) mice with the 64-electrode array. Activation times, end of repolarization times, and activation-recovery intervals (ARIs) were recorded along with limb lead ECGs. ARIs were shorter in the left as compared to right ventricular leads (P<0.05). The global dispersion of repolarization, interventricular and apicobasal repolarization gradients were greater in DM than in healthy animals (P<0.03). The increased dispersion of repolarization and apicobasal repolarization gradient in DM correlated with the prolonged QTc and Tpeak-Tend intervals, respectively. The increased ventricular repolarization heterogeneity corresponded to the electrocardiographic markers was demonstrated in DM.
OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Cardiac repolarization is prolonged in diabetes mellitus (DM), however the distribution of repolarization durations in diabetic hearts is unknown. We estimated the ventricular repolarization pattern and its relation to the ECG phenomena in diabetic mice. Potential mapping was performed on the anterior ventricular surface in healthy (n=18) and alloxan-induced diabetic (n=12) mice with the 64-electrode array. Activation times, end of repolarization times, and activation-recovery intervals (ARIs) were recorded along with limb lead ECGs. ARIs were shorter in the left as compared to right ventricular leads (P<0.05). The global dispersion of repolarization, interventricular and apicobasal repolarization gradients were greater in DM than in healthy animals (P<0.03). The increased dispersion of repolarization and apicobasal repolarization gradient in DM correlated with the prolonged QTc and Tpeak-Tend intervals, respectively. The increased ventricular repolarization heterogeneity corresponded to the electrocardiographic markers was demonstrated in DM.
Key concepts: Ventricular Repolarization, Cardiology, Diabetes mellitus, Internal medicine, Repolarization, Medicine, Endocrinology, Electrophysiology