Use of a root-form implant as a dental pin in a submerged canine for prosthesis support: a case report.

Evian Ci, Caldwell Tl

Open publisher page 0 citations

Abstract

A cavity was prepared in a submerged and impacted maxillary canine in the location of a missing lateral incisor. An 8-mm-long Screw-Vent implant was threaded into the site to function as a dental pin via mechanical retention. A Swede-Vent implant was placed in the area of the adjacent central incisor. After a 6-month submerged healing period, the Swede-Vent implant had clinically osseointegrated, and no breakdown of the dental tissue around the Screw-Vent implant was observed. The implants were restored with a two-unit splinted fixed prosthesis.

About this research paper

What this paper is about

A cavity was prepared in a submerged and impacted maxillary canine in the location of a missing lateral incisor. An 8-mm-long Screw-Vent implant was threaded into the site to function as a dental pin via mechanical retention. A Swede-Vent implant was placed in the area of the adjacent central incisor. After a 6-month submerged healing period, the Swede-Vent implant had clinically osseointegrated, and no breakdown of the dental tissue around the Screw-Vent implant was observed. The implants were restored with a two-unit splinted fixed prosthesis.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A cavity was prepared in a submerged and impacted maxillary canine in the location of a missing lateral incisor. An 8-mm-long Screw-Vent implant was threaded into the site to function as a dental pin via mechanical retention. A Swede-Vent implant was placed in the area of the adjacent central incisor. After a 6-month submerged healing period, the Swede-Vent implant had clinically osseointegrated, and no breakdown of the dental tissue around the Screw-Vent implant was observed. The implants were restored with a two-unit splinted fixed prosthesis.

Key concepts: Osseointegration, Implant, Dentistry, Prosthesis, Maxillary canine, Dental prosthesis, Lateral incisor, Maxillary incisor

Related papers

Back to paper searchBrowse research topicsOriginal source
Use of a root-form implant as a dental pin in a submerged canine for prosthesis support: a case report. — Research Paper | ScholarLens