BACKGROUND AND OBJECTIVE: The aim of this study was to evaluate the results of myopic excimer laser photorefractive keratectomy (PRK) performed using three different ablation approaches. PATIENTS AND METHODS: Using the Apex excimer laser (Summit Technology, Inc., Waltham MA), we have treated 75 eyes. Twenty-five of them were treated by a single ablation zone (SA, 6.5 mm diameter) to correct myopia of -4.50 +/- 2.10 D (mean +/- SD); 25 eyes underwent PRK for the correction of myopia of -4.98 +/- 2.17 D using a multipass multizone technique (MP, 3 zones); and 25 eyes were corrected for myopia of -5.03 +/- 1.98 D using new software which enables the creation of three ablation zones in a single-pass fashion (MZ). RESULTS: Mean refractive error (+/-SD) at the first post-operative month was +1.34 +/- 1.00 D for SA, +1.78 +/- 1.49 D for MP, and +0.90 +/- 0.75 D for MZ. Eyes treated by MZ had significantly better uncorrected visual acuity than those treated by SA (P=0.04). Corneal topography revealed a central island in 14 eyes (56%) of those treated by SA and 2 eyes (8%) of those treated by MZ, but in no eyes treated by MP. Six months after treatment, mean refractive error was +0.28 +/- 0.75 D for SA, +0.36 +/- 0.92 D for MP, and - 0.07 +/- 0.77 D for MZ. CONCLUSION: MZ ablation induced less hyperopic shift at 1 month, thus leading to a faster visual recovery and better uncorrected visual acuity. MP and MZ ablations proved effective in preventing central island formation, thus inducing less visual disturbances than SA ablations. These results suggest that MZ ablation may be preferable to the other techniques in performing myopic PRK.
OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND AND OBJECTIVE: The aim of this study was to evaluate the results of myopic excimer laser photorefractive keratectomy (PRK) performed using three different ablation approaches. PATIENTS AND METHODS: Using the Apex excimer laser (Summit Technology, Inc., Waltham MA), we have treated 75 eyes. Twenty-five of them were treated by a single ablation zone (SA, 6.5 mm diameter) to correct myopia of -4.50 +/- 2.10 D (mean +/- SD); 25 eyes underwent PRK for the correction of myopia of -4.98 +/- 2.17 D using a multipass multizone technique (MP, 3 zones); and 25 eyes were corrected for myopia of -5.03 +/- 1.98 D using new software which enables the creation of three ablation zones in a single-pass fashion (MZ). RESULTS: Mean refractive error (+/-SD) at the first post-operative month was +1.34 +/- 1.00 D for SA, +1.78 +/- 1.49 D for MP, and +0.90 +/- 0.75 D for MZ. Eyes treated by MZ had significantly better uncorrected visual acuity than those treated by SA (P=0.04). Corneal topography revealed a central island in 14 eyes (56%) of those treated by SA and 2 eyes (8%) of those treated by MZ, but in no eyes treated by MP. Six months after treatment, mean refractive error was +0.28 +/- 0.75 D for SA, +0.36 +/- 0.92 D for MP, and - 0.07 +/- 0.77 D for MZ. CONCLUSION: MZ ablation induced less hyperopic shift at 1 month, thus leading to a faster visual recovery and better uncorrected visual acuity. MP and MZ ablations proved effective in preventing central island formation, thus inducing less visual disturbances than SA ablations. These results suggest that MZ ablation may be preferable to the other techniques in performing myopic PRK.
Key concepts: Photorefractive keratectomy, Medicine, Ablation, Ophthalmology, Refractive error, Excimer, Visual acuity, Excimer laser