Reliability of Refractive Measurement by Hand-held Autorefractor
Tae Yoon La, Jae Ryong Oh
Abstract
Tae Yoon La, Jae Ryong Oh
Abstract
Purpose: We tried to evaluate the reliablility of refractive measurement by hand-held autorefractor (HHAR). Methods: Ninety patients (180 eyes) with simple refractive error were divided into three groups (30 patients each) according to their ages. Group I is under 6 years old; group 11, from 7 to 15 years old; and group 3, over 16 years old. Under cycloplegics, three measuring methods of refraction using table top autorefractor (Model 599, Zeiss Humphrey, USA), hand-held autorefractor (Retinomax K-plus, Nikon, Japan) and skiascope (Heine beta 200, Germany) were performed and we compared each spherical and cylindrical value in 3 groups. Results: There was no significant difference in both spherical and cylindrical value between HH-AR and skiascope in all groups (=0.579, =0.708, =0,80l, =0.730, =0.816, =0.754), But there was significant difference in both spherical and cylindrical value between table top autorefractor and skiascope in group I (=0.019, =0.030, =0.405, =0.392, =0.876, =0.747). Conclusions: We believe that hand-held autorefractor can be a useful instrument to measure refractive power without serious error, especially in patients who have difficulty with table top autorefractor.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Purpose: We tried to evaluate the reliablility of refractive measurement by hand-held autorefractor (HHAR). Methods: Ninety patients (180 eyes) with simple refractive error were divided into three groups (30 patients each) according to their ages. Group I is under 6 years old; group 11, from 7 to 15 years old; and group 3, over 16 years old. Under cycloplegics, three measuring methods of refraction using table top autorefractor (Model 599, Zeiss Humphrey, USA), hand-held autorefractor (Retinomax K-plus, Nikon, Japan) and skiascope (Heine beta 200, Germany) were performed and we compared each spherical and cylindrical value in 3 groups. Results: There was no significant difference in both spherical and cylindrical value between HH-AR and skiascope in all groups (=0.579, =0.708, =0,80l, =0.730, =0.816, =0.754), But there was significant difference in both spherical and cylindrical value between table top autorefractor and skiascope in group I (=0.019, =0.030, =0.405, =0.392, =0.876, =0.747). Conclusions: We believe that hand-held autorefractor can be a useful instrument to measure refractive power without serious error, especially in patients who have difficulty with table top autorefractor.
Key concepts: Autorefractor, Medicine, Optometry, Refraction, Refractive error, Significant difference, Reliability (semiconductor), Table (database)