[Determination of selenium in selenium-enriched foods by hydride generation atomic absorption spectrometry].

Min Li, Xiaowei Li, Junquan Gao

Open publisher page 0 citations

Abstract

OBJECTIVE: To determine selenium (Se) in selenium-enriched foods by hydride generation atomic absorption spectrometry. METHODS: The samples were digested by HNO3-HCLO4 and reduced by NaHB4, and then was determined in 6 mol/L HCL. RESULTS: The results showed that the detectable range, detection limit, recovery rate, and the relative standard deviation(RSD) of the method were 0 - 80.0 microg/L, 0.0056 mg/kg, 92.05% - 103.88%, and 1.34% - 3.81% respectively. CONCLUSION: This method is suitable for selenium determination.

About this research paper

What this paper is about

OBJECTIVE: To determine selenium (Se) in selenium-enriched foods by hydride generation atomic absorption spectrometry. METHODS: The samples were digested by HNO3-HCLO4 and reduced by NaHB4, and then was determined in 6 mol/L HCL. RESULTS: The results showed that the detectable range, detection limit, recovery rate, and the relative standard deviation(RSD) of the method were 0 - 80.0 microg/L, 0.0056 mg/kg, 92.05% - 103.88%, and 1.34% - 3.81% respectively. CONCLUSION: This method is suitable for selenium determination.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To determine selenium (Se) in selenium-enriched foods by hydride generation atomic absorption spectrometry. METHODS: The samples were digested by HNO3-HCLO4 and reduced by NaHB4, and then was determined in 6 mol/L HCL. RESULTS: The results showed that the detectable range, detection limit, recovery rate, and the relative standard deviation(RSD) of the method were 0 - 80.0 microg/L, 0.0056 mg/kg, 92.05% - 103.88%, and 1.34% - 3.81% respectively. CONCLUSION: This method is suitable for selenium determination.

Key concepts: Selenium, Hydride, Atomic absorption spectroscopy, Chemistry, Detection limit, Relative standard deviation, Mass spectrometry, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of selenium in selenium-enriched foods by hydride generation atomic absorption spectrometry]. — Research Paper | ScholarLens