[Effects of positive end expiratory pressure on oxygen transport].
Irene Osorio Silla, J Porta, P. Vila, R Montero-Benzo
Abstract
Irene Osorio Silla, J Porta, P. Vila, R Montero-Benzo
Abstract
Fifteen patients admitted at the ICU of our hospital suffering from respiratory failure and submitted to mechanical ventilation were included in a study upon the influence of positive end expiratory pressure (PEEP) on oxygen transport. When the PaO2/FiO2 index was less than 300, 200, and 150, PEEP of +5, +10, and +15 cmH2O respectively was introduced. A Swan-Ganz catheter in the pulmonary artery and a catheter in a radial artery were inserted with the aim to obtain mixed venous blood samples and determine cardiac output, and vascular pulmonary resistances for each PEEP value. When PEEP increased from 5 cmH2O to 15 cmH2O, oxygen supply decreased a 12.4% (p less than 0.05), oxygen extraction from the tissues increased a 21.4% (p less than 0.025) and cardiac output decreased a 7.9% (p less than 0.02) while vascular pulmonary resistances increased a 6.6% (p = NS). We conclude that a PEEP of 5 cmH2O impairs tissue oxygenation when compared with PEEP of 5 cmH2O and that oxygen supply decrease with cardiac output.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Fifteen patients admitted at the ICU of our hospital suffering from respiratory failure and submitted to mechanical ventilation were included in a study upon the influence of positive end expiratory pressure (PEEP) on oxygen transport. When the PaO2/FiO2 index was less than 300, 200, and 150, PEEP of +5, +10, and +15 cmH2O respectively was introduced. A Swan-Ganz catheter in the pulmonary artery and a catheter in a radial artery were inserted with the aim to obtain mixed venous blood samples and determine cardiac output, and vascular pulmonary resistances for each PEEP value. When PEEP increased from 5 cmH2O to 15 cmH2O, oxygen supply decreased a 12.4% (p less than 0.05), oxygen extraction from the tissues increased a 21.4% (p less than 0.025) and cardiac output decreased a 7.9% (p less than 0.02) while vascular pulmonary resistances increased a 6.6% (p = NS). We conclude that a PEEP of 5 cmH2O impairs tissue oxygenation when compared with PEEP of 5 cmH2O and that oxygen supply decrease with cardiac output.
Key concepts: Positive end-expiratory pressure, Cardiac output, Pulmonary artery catheter, Medicine, Cardiac index, Pulmonary artery, Anesthesia, Oxygenation