2012PubMedRequires access

[Depth of focus in spherical and aspheric intraocular lenses].

Nan Li, Xin Tang, Yongji Liu

Open publisher page 0 citations

Abstract

OBJECTIVE: To investigate depth of focus (DOF) in spherical and aspheric IOL eye models. METHODS: Computer numerical simulation experiment was used. IOL eye model based on Liou-Brennan eye model was constructed by using ZEMAX optical design software. Different IOL were implanted in this eye model. Monochromatic through focus modulation transfer function (MTF) curves were computed. Pupil and aspheric designs' effect on DOF were analyzed. RESULTS: DOF of eye model increased with pupil shrinkage in 550 nm monochromatic light (FY60AD 1.20 D at 6 mm pupil, 1.35 D at 5 mm pupil, 1.70 D at 4 mm pupil, 2.46 D at 3 mm pupil; YA60BBR 1.24 D at 6 mm pupil, 1.48 D at 5 mm pupil, 1.80 D at 4 mm pupil, 2.50 D at 3 mm pupil). MTF in spherical IOL eye model was higher with minus defocus, this trend was obvious at larger pupil. MTF of aspheric IOL eyes were higher than spherical IOL eyes when well focused at 5 mm pupil, while the DOF was lower in aspheric IOL with negative spherical aberration (Tecnis Z9000 1.31 D, FY60AD 1.35 D, CeeOn911 1.55 D, YA60BBR 1.48 D). DOF decreased less in aspheric IOL with zero spherical aberration (LI61AO 1.42 D). CONCLUSIONS: DOF in IOL eye model was higher at smaller pupil. When the pupil was large, well focused aspheric IOL improved optical quality compared with spherical IOL, while DOF and the tolerance to defocus in aspheric IOL were partially lost; this phenomenon was obvious with minus defocus.

About this research paper

What this paper is about

OBJECTIVE: To investigate depth of focus (DOF) in spherical and aspheric IOL eye models. METHODS: Computer numerical simulation experiment was used. IOL eye model based on Liou-Brennan eye model was constructed by using ZEMAX optical design software. Different IOL were implanted in this eye model. Monochromatic through focus modulation transfer function (MTF) curves were computed. Pupil and aspheric designs' effect on DOF were analyzed. RESULTS: DOF of eye model increased with pupil shrinkage in 550 nm monochromatic light (FY60AD 1.20 D at 6 mm pupil, 1.35 D at 5 mm pupil, 1.70 D at 4 mm pupil, 2.46 D at 3 mm pupil; YA60BBR 1.24 D at 6 mm pupil, 1.48 D at 5 mm pupil, 1.80 D at 4 mm pupil, 2.50 D at 3 mm pupil). MTF in spherical IOL eye model was higher with minus defocus, this trend was obvious at larger pupil. MTF of aspheric IOL eyes were higher than spherical IOL eyes when well focused at 5 mm pupil, while the DOF was lower in aspheric IOL with negative spherical aberration (Tecnis Z9000 1.31 D, FY60AD 1.35 D, CeeOn911 1.55 D, YA60BBR 1.48 D). DOF decreased less in aspheric IOL with zero spherical aberration (LI61AO 1.42 D). CONCLUSIONS: DOF in IOL eye model was higher at smaller pupil. When the pupil was large, well focused aspheric IOL improved optical quality compared with spherical IOL, while DOF and the tolerance to defocus in aspheric IOL were partially lost; this phenomenon was obvious with minus defocus.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To investigate depth of focus (DOF) in spherical and aspheric IOL eye models. METHODS: Computer numerical simulation experiment was used. IOL eye model based on Liou-Brennan eye model was constructed by using ZEMAX optical design software. Different IOL were implanted in this eye model. Monochromatic through focus modulation transfer function (MTF) curves were computed. Pupil and aspheric designs' effect on DOF were analyzed. RESULTS: DOF of eye model increased with pupil shrinkage in 550 nm monochromatic light (FY60AD 1.20 D at 6 mm pupil, 1.35 D at 5 mm pupil, 1.70 D at 4 mm pupil, 2.46 D at 3 mm pupil; YA60BBR 1.24 D at 6 mm pupil, 1.48 D at 5 mm pupil, 1.80 D at 4 mm pupil, 2.50 D at 3 mm pupil). MTF in spherical IOL eye model was higher with minus defocus, this trend was obvious at larger pupil. MTF of aspheric IOL eyes were higher than spherical IOL eyes when well focused at 5 mm pupil, while the DOF was lower in aspheric IOL with negative spherical aberration (Tecnis Z9000 1.31 D, FY60AD 1.35 D, CeeOn911 1.55 D, YA60BBR 1.48 D). DOF decreased less in aspheric IOL with zero spherical aberration (LI61AO 1.42 D). CONCLUSIONS: DOF in IOL eye model was higher at smaller pupil. When the pupil was large, well focused aspheric IOL improved optical quality compared with spherical IOL, while DOF and the tolerance to defocus in aspheric IOL were partially lost; this phenomenon was obvious with minus defocus.

Key concepts: Pupil, Spherical aberration, Optics, Entrance pupil, Monochromatic color, Depth of focus (tectonics), Optical transfer function, Zemax

Related papers

Back to paper searchBrowse research topicsOriginal source
[Depth of focus in spherical and aspheric intraocular lenses]. — Research Paper | ScholarLens