2015•PubMedRequires access

[Metastasized renal cell carcinoma. Measurement of plasma levels of the tyrosine kinase inhibitors sunitinib, sorafenib and pazopanib].

Corinna Nora Keil, L. Götze, Peter Jochen Olbert, Rainer W. Hofmann, Wolfgang Andreas Nockher, Axel Hegele

Open publisher page 3 citations

Abstract

BACKGROUND: Several tyrosine kinase inhibitors (TKI) are used in the treatment of metastasized renal cell carcinoma (mRCC). This article presents a feasibility study for the measurement of plasma levels of sunitinib, sorafenib and pazopanib using liquid chromatography tandem mass spectrometry (LC-MS/MS). METHODS: A total of 23 patients suffering from mRCC under treatment with sunitinib (n=16), sorafenib (n=3) and pazopanib (n=4) were included. Plasma samples (100 µl) were separated by liquid chromatographic analysis and the plasma levels of the TKIs determined by tandem mass spectrometry. RESULTS: The plasma levels of sunitinib, sorafenib and pazopanib were measurable and the results reproducible. During storage of the plasma samples for 1 week at 4°C no significant decrease of the initial concentration was found. The highest plasma levels detected were 99 ng/ml for sunitinib, 9.8 µg/ml for sorafenib and 63 µg/ml for pazopanib. We could show variability in plasma levels according to changes in dosage of TKIs or during treatment-free intervals. CONCLUSION: Measurement of TKI plasma levels using LC-MS/MS is feasible. Further clinical studies have to be conducted to examine if there are any threshold levels for the incidence of adverse events or response to treatment.

About this research paper

What this paper is about

BACKGROUND: Several tyrosine kinase inhibitors (TKI) are used in the treatment of metastasized renal cell carcinoma (mRCC). This article presents a feasibility study for the measurement of plasma levels of sunitinib, sorafenib and pazopanib using liquid chromatography tandem mass spectrometry (LC-MS/MS). METHODS: A total of 23 patients suffering from mRCC under treatment with sunitinib (n=16), sorafenib (n=3) and pazopanib (n=4) were included. Plasma samples (100 µl) were separated by liquid chromatographic analysis and the plasma levels of the TKIs determined by tandem mass spectrometry. RESULTS: The plasma levels of sunitinib, sorafenib and pazopanib were measurable and the results reproducible. During storage of the plasma samples for 1 week at 4°C no significant decrease of the initial concentration was found. The highest plasma levels detected were 99 ng/ml for sunitinib, 9.8 µg/ml for sorafenib and 63 µg/ml for pazopanib. We could show variability in plasma levels according to changes in dosage of TKIs or during treatment-free intervals. CONCLUSION: Measurement of TKI plasma levels using LC-MS/MS is feasible. Further clinical studies have to be conducted to examine if there are any threshold levels for the incidence of adverse events or response to treatment.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Several tyrosine kinase inhibitors (TKI) are used in the treatment of metastasized renal cell carcinoma (mRCC). This article presents a feasibility study for the measurement of plasma levels of sunitinib, sorafenib and pazopanib using liquid chromatography tandem mass spectrometry (LC-MS/MS). METHODS: A total of 23 patients suffering from mRCC under treatment with sunitinib (n=16), sorafenib (n=3) and pazopanib (n=4) were included. Plasma samples (100 µl) were separated by liquid chromatographic analysis and the plasma levels of the TKIs determined by tandem mass spectrometry. RESULTS: The plasma levels of sunitinib, sorafenib and pazopanib were measurable and the results reproducible. During storage of the plasma samples for 1 week at 4°C no significant decrease of the initial concentration was found. The highest plasma levels detected were 99 ng/ml for sunitinib, 9.8 µg/ml for sorafenib and 63 µg/ml for pazopanib. We could show variability in plasma levels according to changes in dosage of TKIs or during treatment-free intervals. CONCLUSION: Measurement of TKI plasma levels using LC-MS/MS is feasible. Further clinical studies have to be conducted to examine if there are any threshold levels for the incidence of adverse events or response to treatment.

Key concepts: Pazopanib, Sunitinib, Sorafenib, Medicine, Renal cell carcinoma, Tyrosine-kinase inhibitor, Internal medicine, Tyrosine kinase

Back to paper searchBrowse research topicsOriginal source
[Metastasized renal cell carcinoma. Measurement of plasma levels of the tyrosine kinase inhibitors sunitinib, sorafenib and pazopanib]. — Research Paper | ScholarLens