1991PubMedRequires access

Influence of clasp design of distal extension removable partial dentures on the periodontium of the abutment teeth.

H.J.M. Hosman

Open publisher page 15 citations

Abstract

Three removable partial denture designs were investigated to determine the effect of minor connector configuration on the periodontal health of abutment teeth. Twenty-five patients wore three different removable partial dentures for 19 weeks each. The first removable partial denture placed a tilting force on the abutment teeth; the second was stress-releasing; and the third collected the least amount of plaque. Plaque accumulation, the condition of the periodontium, migration of the abutment teeth, deformation of the clasp arms, retention of the prosthesis, and patient preferences were assessed. The results demonstrated that the partial denture retentive design did not affect plaque formation. The prosthesis designed to place a tilting force on the abutment teeth appeared to cause the least mobility and migration of the abutments and had the greatest acceptance by the patients.

About this research paper

What this paper is about

Three removable partial denture designs were investigated to determine the effect of minor connector configuration on the periodontal health of abutment teeth. Twenty-five patients wore three different removable partial dentures for 19 weeks each. The first removable partial denture placed a tilting force on the abutment teeth; the second was stress-releasing; and the third collected the least amount of plaque. Plaque accumulation, the condition of the periodontium, migration of the abutment teeth, deformation of the clasp arms, retention of the prosthesis, and patient preferences were assessed. The results demonstrated that the partial denture retentive design did not affect plaque formation. The prosthesis designed to place a tilting force on the abutment teeth appeared to cause the least mobility and migration of the abutments and had the greatest acceptance by the patients.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Three removable partial denture designs were investigated to determine the effect of minor connector configuration on the periodontal health of abutment teeth. Twenty-five patients wore three different removable partial dentures for 19 weeks each. The first removable partial denture placed a tilting force on the abutment teeth; the second was stress-releasing; and the third collected the least amount of plaque. Plaque accumulation, the condition of the periodontium, migration of the abutment teeth, deformation of the clasp arms, retention of the prosthesis, and patient preferences were assessed. The results demonstrated that the partial denture retentive design did not affect plaque formation. The prosthesis designed to place a tilting force on the abutment teeth appeared to cause the least mobility and migration of the abutments and had the greatest acceptance by the patients.

Key concepts: Abutment, Removable partial denture, Dentures, Periodontium, Dentistry, Prosthesis, Dental Abutments, Orthodontics

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of clasp design of distal extension removable partial dentures on the periodontium of the abutment teeth. — Research Paper | ScholarLens