Influence of urea on HbA1c-determinations by Menarini HA-8140 and on the difference between immunoturbidimetric and HPLC-HbA1c-results.
James F Thoma, F Stirn, D Kutter
Abstract
James F Thoma, F Stirn, D Kutter
Abstract
A secondary peak (#C) included in the HbA1c-calculation by the HA-8140 HPLC (Menarini) shows a fairly good correlation with serum urea. The correlation with HbA1c and with serum glucose is at first glance significant but reveals at a closer look being biased by some incorrect assumptions. The difference between immunoturbidimetric determination (Tinaquant HbA1c II Roche) and HPLC shows a similar behaviour to urea as does the #C-peak of the chromatographic separation. This peak as well as the difference between both determinations of HbA1c could be attributed to carbamylated haemoglobin. The definitive identity has to be proven. This peak could be a monitoring tool for long-time urea. The integration of this peak into total HbA1c by the HA-8140 (Menarini) can lead to a false diagnosis of diabetes in non-diabetic patients with elevated urea.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A secondary peak (#C) included in the HbA1c-calculation by the HA-8140 HPLC (Menarini) shows a fairly good correlation with serum urea. The correlation with HbA1c and with serum glucose is at first glance significant but reveals at a closer look being biased by some incorrect assumptions. The difference between immunoturbidimetric determination (Tinaquant HbA1c II Roche) and HPLC shows a similar behaviour to urea as does the #C-peak of the chromatographic separation. This peak as well as the difference between both determinations of HbA1c could be attributed to carbamylated haemoglobin. The definitive identity has to be proven. This peak could be a monitoring tool for long-time urea. The integration of this peak into total HbA1c by the HA-8140 (Menarini) can lead to a false diagnosis of diabetes in non-diabetic patients with elevated urea.
Key concepts: Urea, Chemistry, High-performance liquid chromatography, Significant difference, Chromatography, Internal medicine, Biochemistry, Medicine