Abstract

A secondary peak (#C) included in the HbA1c-calculation by the HA-8140 HPLC (Menarini) shows a fairly good correlation with serum urea. The correlation with HbA1c and with serum glucose is at first glance significant but reveals at a closer look being biased by some incorrect assumptions. The difference between immunoturbidimetric determination (Tinaquant HbA1c II Roche) and HPLC shows a similar behaviour to urea as does the #C-peak of the chromatographic separation. This peak as well as the difference between both determinations of HbA1c could be attributed to carbamylated haemoglobin. The definitive identity has to be proven. This peak could be a monitoring tool for long-time urea. The integration of this peak into total HbA1c by the HA-8140 (Menarini) can lead to a false diagnosis of diabetes in non-diabetic patients with elevated urea.

About this research paper

What this paper is about

A secondary peak (#C) included in the HbA1c-calculation by the HA-8140 HPLC (Menarini) shows a fairly good correlation with serum urea. The correlation with HbA1c and with serum glucose is at first glance significant but reveals at a closer look being biased by some incorrect assumptions. The difference between immunoturbidimetric determination (Tinaquant HbA1c II Roche) and HPLC shows a similar behaviour to urea as does the #C-peak of the chromatographic separation. This peak as well as the difference between both determinations of HbA1c could be attributed to carbamylated haemoglobin. The definitive identity has to be proven. This peak could be a monitoring tool for long-time urea. The integration of this peak into total HbA1c by the HA-8140 (Menarini) can lead to a false diagnosis of diabetes in non-diabetic patients with elevated urea.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A secondary peak (#C) included in the HbA1c-calculation by the HA-8140 HPLC (Menarini) shows a fairly good correlation with serum urea. The correlation with HbA1c and with serum glucose is at first glance significant but reveals at a closer look being biased by some incorrect assumptions. The difference between immunoturbidimetric determination (Tinaquant HbA1c II Roche) and HPLC shows a similar behaviour to urea as does the #C-peak of the chromatographic separation. This peak as well as the difference between both determinations of HbA1c could be attributed to carbamylated haemoglobin. The definitive identity has to be proven. This peak could be a monitoring tool for long-time urea. The integration of this peak into total HbA1c by the HA-8140 (Menarini) can lead to a false diagnosis of diabetes in non-diabetic patients with elevated urea.

Key concepts: Urea, Chemistry, High-performance liquid chromatography, Significant difference, Chromatography, Internal medicine, Biochemistry, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of urea on HbA1c-determinations by Menarini HA-8140 and on the difference between immunoturbidimetric and HPLC-HbA1c-results. — Research Paper | ScholarLens